Installing the airdog, Fp-150 high flow suction tube – PureFlow AirDog FP-150 - 6.0L Ford 2003-2007 User Manual
Page 14
14
AirDog
®
FP-100 & FP-150 Ford PowerStroke 2003-2007 6.0L
Section 5-D Fuel Lines
INSTALLING THE AIRDOG
®
FP-150
HIGH FLOW SUCTION TUBE
The AirDog
®
150 includes a ½” High Flow suction tube to accommodate the high flows of
this system. To install the ½ suction tube it is necessary to either drop the fuel tank or to lift
the truck bed.
NOTE: Should you choose to drop the fuel tank, support the tank as it is when it is installed
on the truck. If you let it rest flat on the floor, the tank may squash out and the suction tube
will be too short after the tank is re-installed in the truck. The suction tube, being cut too
short may suck air as the fuel drops below ¼ tank level.
NOTE: Should you choose to pull the pickup bed to access the tank. Be sure to disconnect
the tail light wires, fuel tank filler tube, and any other accessories or components that may be
secured to the frame and bed.
When Dropping the Tank, Always Remember Safety First!
Figure 29
Figure 30
Figure 31
If you choose to remove the bed, properly support the truck bed to prevent
serious injury or death!
Figure 32
Figure 33