6 Maintenance
15
Press the reset button if your machine is not working properly and a red light comes on just above the
reset button. A green lamp will then light up.
Now press the test button and hold it in for at least 3 seconds. The machine will test all components
and can then be used again.
If your machine is equipped with an automatic lift table and/or punch (optional), and a malfunction
occurs, as a result of which the lift table is not automatically lowered after dispensing, you can solve
this problem by opening the flap and pressing the reset-button. You will find this reset-button on the
inside of the frame, at the right. (figure 6, number 13).
Contact the manufacturer if this procedure does not give the desired result.
When a stirrer malfunction occurs, follow need to be replaced:
HA-s/m :
Pull the stirrer down, turn it anti-clockwise and lift it up.
Put the stirrer in the canister, pull it down and turn it to the right till it stucks.
HA-l:
Pull the stirrer up.
Put the new stirrer in the canister and pull it down to the bottom.
6.4
Service/Service Department
Reset
Test (press in and hold for 3 seconds)
figure 7
Lamp
р
р
р
Turntable is not turning
1. Door and/or lid not closed
properly
2. Piston rod positioned too high
3. Valve mouth pointing down
4. Cable(s) loose
5. Cable or motor defective
1. Close door and/or lid
2. Set piston in lowest position
3. Reposition valve mouth
4. Check cables
5.
1. Check cable
2. Use the software to set the timer
correctly
3.
4.
5.
Close the door(s)
1. Loose cable
2. Timer setting incorrect
3. Defective cable
4. Defective motor
5. Wingdoor or front door open
Stirrer is not rotating