INSTALLATION LAYOUT G

FOR SAFE CLEARANCES

I17 & I34 - 3 FT. MINIMUMG

BROODER TOP TO CEILING

POSITION THE GAS HOSE AND ELECTRICAL POWER CORDG
OUTSIDE OF THE HOT ZONE DIRECTLY ABOVE THE HEATER.G
POSITION THE GAS HOSE AND POWER CORD TO AVOID G
ANY OPPORTUNITY FOR CONTACT WITH THE HOT CANOPYG
SURFACE OF THE HEATER.

MINIMUM 3 FT. CLEARANCEG

TO COMBUSTIBLES

FLOOR

I17 - 3.5 FT. MINIMUMG
I34 - 4.5 FT. MINIMUMG

POINT OF COMBUSTION G

CONE TO FLOORG

G

HANG THE HEATER WITH THE G
CONTROL END 1 TO 5 DEGREES DOWN G
FROM HORIZONTAL (SEE BELOW)

CONTROL PANEL

GAS PIPING

FIG. 2

3 FT. MINIMUM

BROODER TOP TO CEILING

4.5 FT. MINIMUM

POINT OF COMBUSTION

CONE TO FLOOR

-- With the main burner in operation, check all

connections, hose connections, fittings and

joints as well as the gas control valve inlet and

outlet connections with approved gas leak

detectors.

-- If a leak is detected, check the components

involved for cleanliness in the thread areas and

proper application of pipe compound before

further tightening.

-- Tighten the gas connection as necessary to

stop the leak.

-- If necessary, replace the parts or components

involved if the leak cannot be stopped.

-- Ensure all gas leaks have been identified and

repaired before proceeding.

11. A qualified service agency must check for proper

operating gas pressures upon installation of the

heaters.

12. It is extremely important to use the proper gas supply

line to assure proper functioning of the heaters.

Typically, 1/2 in. ID black iron pipe is used to convey

the gas to the heaters. However, always consult your

fuel gas supplier, or the L. B. White Co., Inc. for proper

line sizing and installation.

13. Infraconic heaters require a regulated gas supply to

the gas inlet. Exceeding the gas inlet pressure rating

can result in poor performance and unreliable

operation. Refer to page 4 of this manual for

information on gas pressures relating to specific

models.

14. The heater is designed for either L.P. vapor withdrawal

or natural gas, depending on model number. Do not

use this heater in an LPG liquid withdrawal

system. Do not permit LPG in liquid form to enter the

heater at any time.

15. The corrosive atmosphere present in animal

confinement buildings can cause component failure or

heater malfunction. The heater should be periodically

inspected and cleaned in accordance with the

Maintenance and Cleaning Instructions in this manual.

Make sure that livestock is protected by a back up

alarm system that limits high and low temperatures

and also activates appropriate alarms.

16. Take time to understand how to operate and maintain

the heater using the owner’s manual. Make sure you

know how to shut off the gas supply to the building

and to the individual heaters. Contact your gas

supplier if you have any questions.

17. Any defects found in performing any of the service

procedures must be eliminated and defective parts

replaced immediately. Retest the heater before

placing it back into service.

AATTTTEENNTTIIOONN

Model I34 heaters use an

integral hanging bracket with

key ring for hanging the heater.

Attach only steel cable or chain

to the key ring. Do not use

combustible hanging materials

such as ropes, lines, etc.

The installer must make sure

that the heater is hung so

control end of heater is

positioned 1º to 5º down from

horizontal after gas supply

hose is attached.This allows

proper venting of heater and

eliminates potential heat

damage to optional dust filter.

Repositioning of factory

installed key ring into hanging

bracket may be required.

Refer to following illustrations.

THIS

NOT THIS

CONTROL END

KEYRING

STEEL CABLE

HANGING

CONTROL END

OR CHAIN

BRACKET

OF HEATER

MUST BE 1 TO 5 DOWN

FROM HORIZONTAL