Installation layout g, Fig. 2, This not this – L.B. White I-34 Infraconic Spark Ignition User Manual
Page 9
88
INSTALLATION LAYOUT G
FOR SAFE CLEARANCES
I17 & I34 - 3 FT. MINIMUMG
BROODER TOP TO CEILING
POSITION THE GAS HOSE AND ELECTRICAL POWER CORDG
OUTSIDE OF THE HOT ZONE DIRECTLY ABOVE THE HEATER.G
POSITION THE GAS HOSE AND POWER CORD TO AVOID G
ANY OPPORTUNITY FOR CONTACT WITH THE HOT CANOPYG
SURFACE OF THE HEATER.
MINIMUM 3 FT. CLEARANCEG
TO COMBUSTIBLES
FLOOR
I17 - 3.5 FT. MINIMUMG
I34 - 4.5 FT. MINIMUMG
POINT OF COMBUSTION G
CONE TO FLOORG
G
HANG THE HEATER WITH THE G
CONTROL END 1 TO 5 DEGREES DOWN G
FROM HORIZONTAL (SEE BELOW)
CONTROL PANEL
GAS PIPING
FIG. 2
3 FT. MINIMUM
BROODER TOP TO CEILING
4.5 FT. MINIMUM
POINT OF COMBUSTION
CONE TO FLOOR
-- With the main burner in operation, check all
connections, hose connections, fittings and
joints as well as the gas control valve inlet and
outlet connections with approved gas leak
detectors.
-- If a leak is detected, check the components
involved for cleanliness in the thread areas and
proper application of pipe compound before
further tightening.
-- Tighten the gas connection as necessary to
stop the leak.
-- If necessary, replace the parts or components
involved if the leak cannot be stopped.
-- Ensure all gas leaks have been identified and
repaired before proceeding.
11. A qualified service agency must check for proper
operating gas pressures upon installation of the
heaters.
12. It is extremely important to use the proper gas supply
line to assure proper functioning of the heaters.
Typically, 1/2 in. ID black iron pipe is used to convey
the gas to the heaters. However, always consult your
fuel gas supplier, or the L. B. White Co., Inc. for proper
line sizing and installation.
13. Infraconic heaters require a regulated gas supply to
the gas inlet. Exceeding the gas inlet pressure rating
can result in poor performance and unreliable
operation. Refer to page 4 of this manual for
information on gas pressures relating to specific
models.
14. The heater is designed for either L.P. vapor withdrawal
or natural gas, depending on model number. Do not
use this heater in an LPG liquid withdrawal
system. Do not permit LPG in liquid form to enter the
heater at any time.
15. The corrosive atmosphere present in animal
confinement buildings can cause component failure or
heater malfunction. The heater should be periodically
inspected and cleaned in accordance with the
Maintenance and Cleaning Instructions in this manual.
Make sure that livestock is protected by a back up
alarm system that limits high and low temperatures
and also activates appropriate alarms.
16. Take time to understand how to operate and maintain
the heater using the owner’s manual. Make sure you
know how to shut off the gas supply to the building
and to the individual heaters. Contact your gas
supplier if you have any questions.
17. Any defects found in performing any of the service
procedures must be eliminated and defective parts
replaced immediately. Retest the heater before
placing it back into service.
AATTTTEENNTTIIOONN
■
Model I34 heaters use an
integral hanging bracket with
key ring for hanging the heater.
■
Attach only steel cable or chain
to the key ring. Do not use
combustible hanging materials
such as ropes, lines, etc.
■
The installer must make sure
that the heater is hung so
control end of heater is
positioned 1º to 5º down from
horizontal after gas supply
hose is attached.This allows
proper venting of heater and
eliminates potential heat
damage to optional dust filter.
■
Repositioning of factory
installed key ring into hanging
bracket may be required.
■
Refer to following illustrations.
THIS
NOT THIS
CONTROL END
KEYRING
STEEL CABLE
HANGING
CONTROL END
OR CHAIN
BRACKET
OF HEATER
MUST BE 1 TO 5 DOWN
FROM HORIZONTAL