Maintenance instructions, Service instructions, Maintenance instructions service instructions – L.B. White I-34 Infraconic Spark Ignition User Manual
Page 14: General

1133
1. Have your gas supplier check all gas piping annually
for leaks or restrictions in gas lines. Also, at this time
have your gas supplier clean out the sediment trap on
the zone control panel of any debris that may have
accumulated.
2. TThhee hheeaatteerr’’ss ssuurrrroouunnddiinngg aarreeaa sshhaallll bbee kkeepptt cclleeaarr aanndd
ffrreeee ffrroom
m ccoom
mbbuussttiibbllee m
maatteerriiaallss,, ggaassoolliinnee,, aanndd ootthheerr
ffllaam
mm
maabbllee vvaappoorrss aanndd lliiqquuiiddss..
3. Regulators can wear out and function improperly.
Have your gas supplier check the date codes on all
regulators installed and check delivery pressures to
the appliance to make sure that the regulator is
suitable for continued use.
4. Regulators must be periodically inspected to make
sure the regulator vents are not blocked. Debris,
insects, insect nests, snow, or ice on a regulator can
block vents and cause excess pressure at the
appliance.
5. For safety as well as for optimum performance at the
heater, it is necessary to keep the inside and the
outside of the heater free of dust, dirt or any
combustible material. If any operational component
shows signs of rust or corrosion, replace the
component immediately.
6. If any warning or instruction labels, dataplates, etc.
become lost or hard to read, replace them
immediately. Do not operate the heater until you
have all instructions and can read and understand
them.
7. Check overall condition of heater for cracked or
damaged components, loose screws or bolts, etc.
Replace any suspect components.
8. Check all hose and tubing assemblies for cracks,
abrasions or ruptures. Replace any hoses that are
suspect.
If it becomes apparent that a dark spot has formed part way
up on the inner combustion cone or a build up of debris is
occurring in the bottom of the inner cone, it will be
necessary to clean out the combustion cone assembly.
Refer to “Cleaning Instructions”.
Maintenance Instructions
Service Instructions
GENERAL
1. Close the fuel supply valve to the heater and
disconnect the heater’s electrical supply before
servicing unless it is necessary to have the valve open
and electrical supply connected for your service
procedure.
2. In servicing some components, it may be necessary to
remove optional filter kit.
3. Remove the control box cover for access to ignition
control,high limit switch, and on/off switch.
4. For reassembly, reverse the respective service
procedure. Ensure gas connections are tightened
securely.
5. After servicing, start the heater to ensure proper
operation and check for gas leaks.
6. CClleeaann tthhee hheeaatteerr’’ss oorriiffiicceess wwiitthh ccoom
mpprreesssseedd aaiirr oorr aa
ssoofftt,, ddrryy rraagg.. DDoo nnoott uussee ffiilleess,, ddrriillllss,, bbrrooaacchheess,, eettcc.. ttoo
cclleeaann tthhee oorriiffiiccee hhoolleess.. DDooiinngg ssoo wwiillll eennllaarrggee tthhee hhoollee,,
ccaauussiinngg ccoom
mbbuussttiioonn oorr iiggnniittiioonn pprroobblleem
mss.. RReeppllaaccee tthhee
oorriiffiiccee iiff iitt ccaannnnoott bbee cclleeaanneedd pprrooppeerrllyy..
W
WAARRNNIINNGG
FFiirree aanndd EExxpplloossiioonn HHaazzaarrdd
■
Do not disassemble or attempt to repair any heater
components or gas train components.
■
All component parts must be replaced if defects are
found.
■
Failure to follow this warning will result in fire or
explosions, causing property damage, injury, or death.
W
WAARRNNIINNGG
BBuurrnn HHaazzaarrdd
■
Heater surfaces are extrememly hot for a period of
time after the heater has been shut down.
■
Allow the heater to cool before performing service,
maintenance, or cleaning.
■
Failure to follow this warning will result in burns
causing injury.