Burner orifice, On/off switch, Ignition module – L.B. White I-34 Infraconic Spark Ignition User Manual
Page 15
IGNITION LEAD
IGNITION CONTROLG
MOUNTING SCREWS
■
Handle the module at the edges of the board
■
Do not touch or allow any contact to the module
components, otherwise damage may occur.
1. Disconnect all electrical leads from the ignition
control terminals.
2. Disconnect high voltage ignition lead.
3. Remove ignition control module mounting screws.
See Fig. 10.
FIG. 10
ADAPTER
INLET
BUSHING
GROUND LEAD
VALVE GROUNDING ANDG
ATTACHMENT SCREW
G
ADAPTER
VENTURI G
NECK
BURNER ORIFICE
GAS CONTROLG
VALVE
1. Remove valve grounding and attachment screw.
2. Remove injector body with gas control from venturi
tube.
3. Using a 6 mm hex nut driver, remove the orifice.
4. Clean the orifice hole. Reinstall orifice into the orifice
body. Do not overtighten the orifice as overtightening
can strip the threads in the injector body.
FIG. 11
BURNER ORIFICE
BOOT
SWITCH
1. Disconnect the electrical leads from the ON/OFF
switch.
2. Remove the rubber boot from the ON/OFF switch.
See Fig. 9. Remove the switch from the control box.
FIG. 9
ON/OFF SWITCH
1144
IGNITION MODULE
INJECTOR
BODY