Electrical Connection and Ladder Diagram
2211
CAUTION: REFER TO THE HEATER'S ELECTRICAL CONNECTION
DIAGRAM WHEN SERVICING TO AVOID WIRING ERRORS AND HEATER
MALFUNCTION. CHECK FOR PROPER OPERATION AFTER SERVICING.
WARNING: THIS HEATER MAY START AT ANY TIME
HIGH VOLTAGE IGNITER LEAD
IGNITER
RED
RED
GROUND
W
HI
TE
RED
GREEN
BLACK
RED
GROUND
BLACK
BLACK
GR
EE
N
WHITE
SPARK
IGNITION
CONTROL
NOTE: POWER CORD IS
CONNECTED TO
THERMOSTAT OR
BUILDING ENVIRONMENTAL
CONTROL SYSTEM
ELECTRICAL CONNECTION DIAGRAM
N2
N3
GND
L1
MV
ON/OFF
SWITCH
POWER
CORD
GAS
CONTROL
VALVE
GROUND
SPARK
IGNITION
CONTROL
ELECTRICAL LADDER DIAGRAM
N2
N3
GND
L1
MV
ON/OFF
SWITCH
L1
GROUND
IGNITER
SOLENOID
NEUTRAL
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE HEATER
MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL
HAVING A TEMPERATURE RATING OF AT LEAST 302°F (150°C)
HIGH
LIMIT
SWITCH
HIGH LIMIT
SWITCH
150-22824-A
- AW060 (18 pages)
- AW325 (18 pages)
- AW250 (18 pages)
- AD250(Spark Ignition) (30 pages)
- AB250 (18 pages)
- AW250(building controller) (31 pages)
- AD250 (31 pages)
- AW250(Smart Box controller) (31 pages)
- FA-MCS-D (21 pages)
- FA-MCS (22 pages)
- COMBO-MCS (23 pages)
- AD060 (30 pages)
- 60 Classic (16 pages)
- 115 Classic (16 pages)
- 170 Classic (16 pages)
- Pilot (94 pages)
- I-17 Infraconic Spark Ignition (28 pages)
- I-17 Infraconic Spark Ignition (26 pages)
- I-3 Infraconic (26 pages)
- I-5 Infraconic (24 pages)
- I-17 Infraconic (28 pages)
- Guardian with Smart Sense - Hot Surface (60K / 100K) (31 pages)
- Guardian with Smart Sense - Spark Ignition (60K / 100K) (31 pages)
- Guardian with Smart Sense / Direct Connect - Spark Ignition (250K) (30 pages)
- 100 Tradesman Portable Forced Air (24 pages)
- 170 Tradesman Portable Forced Air (28 pages)
- 400 Tradesman Portable Forced Air (30 pages)
- Portable Gas Heaters (99 pages)
- 45-75K Tradesman (30 pages)
- HW 120 Therma Grow (28 pages)
- HW120 Plus Therma Grow (30 pages)
- 220 Therma Grow (30 pages)
- 220 Plus Therma Grow (32 pages)
- 300 Director (27 pages)
- 350 Premier Dual Fuel (33 pages)
- 80 Premier (34 pages)
- 170 Dual Fuel (30 pages)
- 350 Premier (33 pages)
- 100 Workman - Standard LP (18 pages)
- 100 Workman - NG Low Pressure (18 pages)
- 250 Norseman (18 pages)
- 200 Norseman (18 pages)
- 225 Workman (18 pages)
- 322 Norseman - Horizontal (18 pages)
- Sentinel Radiant Tube AT150 40' Center Mount (32 pages)