beautypg.com

Radiant heater specifications, Mmooddeell – L.B. White I-34 Infraconic Spark Ignition User Manual

Page 5

background image

I

34

Maximum Input (Btuh)

34,200

Ventilation Air to Support Combustion

5 psig
5 psig
5 psig

2.0 psig

5 psig

“A”

26-3/8 in.

“B”

20 1/4 in.

“C”

10 3/8 in.

Net Weight

15 lbs. 8 oz.

PROPANE GAS

1.58 lbs./hr.

NATURAL GAS

120/60/1

0.5

CHICKENS

2500 - 3800

TURKEYS

800 - 950

SWINE

300

CHICKENS

6 - 7 ft.

TURKEYS

4.5 ft.

SWINE

4 - 5 ft.

TOP OF HOOD TO CEILING

3 ft.

POINT OF COMBUSTION

CONE TO FLOOR
SIDES

3 ft.

POULTRY

SWINE

44

SSPPEECCIIFFIICCAATTIIOONNSS

Radiant Heater Specifications

FIG. 1

Heater Dimensions

(See Fig. 1)

Fuel Consumption Per Hour

Animal Coverage Per Heater (1)

Minimum Safe Clearances to

Combustible Materials

Recommended Height Installation

For Livestock From Point of

Combustion Cone to Floor

4.5 ft.

34.2 CFH

400 CFM

(1) There are other factors that will affect the quantity of animals

each heater can cover. These include building ventilation and

control systems, building insulation, building size and population

density, etc. Consult your L. B. White dealer or call L. B. White for

specific recommendations for your application.

(2) This is typical sensor placement range. The size and type of

livestock being grown, heater spacing and height, etc. will dictate

sensor location. Care should always be taken to ensure that the

sensor is sufficiently high as to not be damaged by the animal

during operation.

"B"

"A"

"C"

Electrical Supply (Volts/HZ/Phase)

Amp Draw

Animal Occupied Zone Temperature

Control Sensor Location (2)

Inlet Gas Supply Pressure at the Heater

MAX.
MIN.
MAX.
MIN.

VERTICAL FROM FLOOR

6-12 in.

HORIZONTAL FROM BROODER

8-12 ft.

VERTICAL FROM FLOOR

Above Animal Height

HORIZONTAL FROM BROODER

4-8 ft.

M

Mooddeell

FULL OUTPUT

(On/Off

Version)

ZONE

CONTROLLED

(Dual Solenoid

Version)

Burner Manifold Pressure at Maximum Pressure