Heater Specifications
4
AR080
20
80,000
3.70
80
13.5 in. W.C., L.P. and Natural Gas
11.0 in. W.C., L.P. Gas
7.0 in. W.C., Natural Gas
10.0 in. W.C., L.P. Gas
4.0 in. W.C., Natural Gas
140 CFM
Ball Bearing
1/30 H.P., 3020 RPM, CW Rotation
115/60/1
STARTING
1.16
CONTINUOUS
OPERATION
TOP
1 ft.
SIDES
2.5 ft.
DISCHARGE END
6 ft.
BELOW RADIANT
6 ft.
12-18 in. Above Litter and Approx. 10 Ft. Down from Burner Box
Ventilation Air Required
to Support Combustion
Minimum Safe
Distances of Heater
From Nearest
Combustible Materials
(See Fig. 1 on page 5)
Amp Draw
(Starting Amps
Include Igniter)
Motor Characteristics
1.02
Temperature Sensor Location
(See Fig. 2 on page 5)
SPECIFICATIONS
Model
Inlet Gas Supply
Pressure Acceptable
at the Inlet of the
Heater for Purpose of
Input Adjustment
Input per Hour (BTUH)
Tube Length (ft.)
MAX.
MIN.
BurnerManifold
Pressure
Fuel Consumption
per Hour (Max.)
Electrical Supply (Volts/Hz/Phase)
L.P. GAS (lbs.)
NAT. GAS (cu. ft.)
- AW060 (18 pages)
- AW325 (18 pages)
- AW250 (18 pages)
- AD250(Spark Ignition) (30 pages)
- AB250 (18 pages)
- AW250(building controller) (31 pages)
- AD250 (31 pages)
- AW250(Smart Box controller) (31 pages)
- FA-MCS-D (21 pages)
- FA-MCS (22 pages)
- COMBO-MCS (23 pages)
- AD060 (30 pages)
- 60 Classic (16 pages)
- 115 Classic (16 pages)
- 170 Classic (16 pages)
- Pilot (94 pages)
- I-17 Infraconic Spark Ignition (28 pages)
- I-17 Infraconic Spark Ignition (26 pages)
- I-3 Infraconic (26 pages)
- I-5 Infraconic (24 pages)
- I-17 Infraconic (28 pages)
- Guardian with Smart Sense - Hot Surface (60K / 100K) (31 pages)
- Guardian with Smart Sense - Spark Ignition (60K / 100K) (31 pages)
- Guardian with Smart Sense / Direct Connect - Spark Ignition (250K) (30 pages)
- 100 Tradesman Portable Forced Air (24 pages)
- 170 Tradesman Portable Forced Air (28 pages)
- 400 Tradesman Portable Forced Air (30 pages)
- Portable Gas Heaters (99 pages)
- 45-75K Tradesman (30 pages)
- HW 120 Therma Grow (28 pages)
- HW120 Plus Therma Grow (30 pages)
- 220 Therma Grow (30 pages)
- 220 Plus Therma Grow (32 pages)
- 300 Director (27 pages)
- 350 Premier Dual Fuel (33 pages)
- 80 Premier (34 pages)
- 170 Dual Fuel (30 pages)
- 350 Premier (33 pages)
- 100 Workman - Standard LP (18 pages)
- 100 Workman - NG Low Pressure (18 pages)
- 250 Norseman (18 pages)
- 200 Norseman (18 pages)
- 225 Workman (18 pages)
- 322 Norseman - Horizontal (18 pages)
- Sentinel Radiant Tube AT150 40' Center Mount (32 pages)