beautypg.com

Bryant Hat Pump 698B User Manual

Page 8

background image

24 VAC HOT

FAN

R

G

R

G

24 VAC COMM

N/A

OUTDOOR

SENSOR

CONNECTION

C

B

S1

S2

C

C

R

PROGRAMMABLE

THERMOSTAT

MODEL 2S

FV4
FK4

FAN COIL

J1
JUMPER

J2 JUMPER

TWO-SPEED

HEAT PUMP

DH

Y1

Y1

W/W1

O/W2

Y1/W2

O

W1

Y/Y2

Y2

W1

Y/Y2

O

W2

COOL/HEAT
STAGE 1

COOL/HEAT
STAGE 2

HEAT STAGE 3

RVS COOLING

See notes 1, 2, and 3

A01475

R

Y/Y2

R

Y2

C

C

C

R

W1

O

Y1

NON-PROGRAMMABLE

THERMOSTAT

MODEL 2S

FV4
FK4

FAN COIL

TWO-SPEED

HEAT PUMP

J1 JUMPER

J2 JUMPER

G

G

Y/Y2

DH

W/W1

W1

Y1

O/W2

Y1

W2

O

B

S1

S2

24 VAC HOT

24 VAC COMM

FAN

RVS COOLING

OUTDOOR

SENSOR

CONNECTION

HEAT STAGE 3

COOL/HEAT

STAGE 2

COOL/HEAT

STAGE 1

N/A

See notes 1, 2, 3, and 4

A01476

O/W2

W/W1

Y1/W2

G

R

O

Y1

FV4/FK4

FAN COIL

TWO-SPEED

HEAT PUMP

W1

G

W2

C

Y2

R

W1

Y1

O

C

DHUM

HUM

B

S1

S2

Y/Y2

R

C

DH

COOL/HEAT
STAGE 1

HEAT STAGE 3

COOL/HEAT
STAGE 2

RVS COOLING

FAN

24 VAC HOT

24 VAC COMM

DEHUMIDIFY

HUMIDIFY

N/A

OUTDOOR
SENSOR
CONNECTION

Y/Y2

HUMIDIFIER

(24 VAC)

OUTDOOR

SENSOR

J2 JUMPER

REMOVE J1

THERMIDISTAT

CONTROL

MODEL RH

See notes 1, 2, 3, 6, 9, and 10

A01429

O/ W2

W/W1

Y1/W2

G

R

THERMIDISTAT

CONTROL

MODEL RH

SINGLE-STAGE

FURNACE

TWO-SPEED

HEAT PUMP

W

G

Y

C

Y2

W1

R

Y1

O

C

DHUM

HUM

B

S1

S2

R

C

HEAT STAGE 3

COOL/HEAT

STAGE 2

RVS COOLING

FAN

24 VAC HOT

24 VAC COMM

N/A

HUMIDIFY

N/A

OUTDOOR
SENSOR
CONNECTION

Y/Y2

HUMIDIFIER

(24 VAC)

OUTDOOR

SENSOR

COOL/HEAT

STAGE 1

See notes 1, 2, 3, 7, 8, 9, 10, and 11

A01422

W/ W1

G

R

SINGLE-STAGE

FURNACE

TWO-SPEED

HEAT PUMP

W

G

Y

C

Y2

W1

C

L

B

S1

S2

R

R

C

HEAT STAGE 3

(FURNACE)

COOL/HEAT
STAGE 2

(COMPRESSOR HI)

FAN

24 VAC HOT

24 VAC COM

O

O/W2

RVS COOLING

RVS SENSING

N/A

OUTDOOR
SENSOR
CONNECTIONS

Y/ Y2

Y1

COOL/HEAT
STAGE 1

(COMPRESSOR LO)

Y1/W2

OUTDOOR

SENSOR

PROGRAMMABLE

DUAL FUEL

THERMOSTAT

MODEL DF

See notes 1, 2, 3, 7, 8, and 12

A01423

O/W2

W/ W1

Y1/W2

G

R

TWO-STAGE

FURNACE
WITH PSC

BLOWER MOTOR

TWO-SPEED

HEAT PUMP

W/W1

G

Y/Y2

C

Y2

W1

R

Y1

O

C

DHUM

HUM

B

S1

S2

W2

R

C

HEAT STAGE 3

COOL/HEAT
STAGE 1

COOL/HEAT
STAGE 2

RVS COOLING

FAN

24 VAC HOT

24 VAC COMM

N/A

HUMIDIFY

N/A

OUTDOOR
SENSOR
CONNECTION

Y/ Y2

HUMIDIFIER

(24 VAC)

OUTDOOR

SENSOR

THERMIDISTAT

CONTROL

MODEL RH

See notes 1, 2, 3, 5, 7, 8, 9, 10, and 11

A01426

Fig. 13—Typical 24V Circuit Connections

—8—