ELECTRICAL REQUIREMENTS
CAUTION -
The dispenser must be disconnected from the power source until specified in

Initial Set-Up.

The 120 volt version of this dispenser has an attached cordset and requires 2-wire, grounded service rated 120
volts ac, 15 amp, single phase, 60 Hz. The mating connector must be a NEMA 5-15R.

The 230 volt CE version requires 2 wire, grounded service rated 230V ac, single phase, 50 Hz.

The 200 volt or 240 volt versions require 2 wire, grounded service rated 200 volts ac or 240 volts ac, single
phase, 50 Hz.
(

Refer to the dispenser’s data plate for exact voltage requirement.)

Electrical Hook-Up
CAUTION –
Improper electrical installation will damage electronic components.
1. An electrician must provide electrical service as specified.
2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
3. Connect the dispenser to the power source.

PLUMBING REQUIREMENTS

This dispenser must be connected to a cold water system with operating pressure between 20 and 90 (138

and 620 kPa) psi from a

1

2

" or larger supply line. A shut-off valve should be installed in the line before the

dispenser. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345
kPa). The water inlet fitting is

1

4

" flare.

NOTE - Bunn-O-Matic recommends

1

4

" copper tubing for installations of less than 25 feet and

3

8

" for more than

25 feet from the

1

2

" water supply line. At least 18 inches of an FDA approved flexible beverage tubing, such as

reinforced braided polyethylene or silicone, before the brewer will facilitate movement to clean the countertop.
Tubing is supplied by Bunn-O-Matic (part number 00326-0000). Bunn-O-Matic does not recommend the use of
a saddle valve to install the brewer. The size and shape of the hole made in the supply line by this type of device
may restrict water flow

This equipment must be installed to comply with the Basic Plumbing Code of the Building
Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanita-
tion Manual of the Food and Drug Administration (FDA).

INITIAL SET-UP
NOTE:
This refill unit should not be used to initially fill the hopper. Running the motor for extended periods will

trip the thermal switch. The thermal switch will reset, but requires up to 30 minutes of cooling time.

NOTE: Hoses and product container connectors are not supplied. Fitting, clamps and labels are supplied. Make

hose assemblies as required. Refer to

PIPING DIAGRAM

on page 22.

1. Assemble hoppers with probe housing assemblies to CDS-2, CDS-3 or modify existing hoppers using template

provided.

2. Make sure probe housing assembly is pushed down into slots on back of hoppers.
3. Install cable assembly to the lower right front of the auto refill box and the probe housing assemblies on the

hoppers. The connectors on the cable pushes in and cap rotates 1/4 turn to lock into position.

4. Run output tubes from auto refill box to the quick disconnects in the hoppers.

NOTE: Make sure numbers on the labels match up. Cable#1 with Hose#1, Cable#2 with Hose#2,....etc.

28791 040501