beautypg.com

Model 363aap upflow/horizontal oil furnace – Bryant Oil Fired 363AAP 361AAN User Manual

Page 6

background image

—6—

MODEL 363AAP UPFLOW/HORIZONTAL OIL FURNACE

A93213

The 363AAP Furnace is designed for top performance to provide years of reli-
able, comfortable home heating. This furnace is also designed to meet the need
for large residential and light commercial markets.

The 363AAP is a large capacity upflow/horizontal oil furnace that can be installed
upflow, horizontal right, or horizontal left for greater application coverage. The flue
exits the rear of the furnace. The heat exchanger is backed by a Limited Lifetime
Warranty.

FEATURES

INSTALLATION FLEXIBILITY

—The 363AAP installs in either upflow, horizontal

right, or horizontal left orientation for greater application coverage and installation
flexibility.

HEAT EXCHANGER

—The stainless steel primary and aluminized steel second-

ary heat exchangers are designed for outstanding reliability backed by a Limited
Lifetime Warranty. The heat exchanger utilizes crimped seams instead of welds
for corrosion resistance. All internal surfaces are accessible for any field mainte-
nance without removing the heat exchanger.

CONTROLS

—The Beckett oil burner is equipped with an electronic primary relay

for added reliability. Integrated fan timer control board with low-voltage terminal
strip and 40-va transformer make air conditioning installation easy.

HEAVY DUTY BLOWER

—Blower motors are PSC type and 3 speed. The direct-

drive blowers eliminate belt adjustments in the field. The constant low-speed
blower switch provides air circulation during “off” cycles for indoor air filtration.

DURABLE CABINET

—The casing is constructed of prepainted steel for years of

attractiveness. Filter and frame are provided with each furnace.

* Capacity and AFUE in accordance with U.S. Government DOE test procedures.

† Permissible limits of the voltage range at which the unit will operate satisfactorily.
‡ Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop.

** Time-delay fuse is recommended.
ICS—Isolated Combustion System

UNIT SIZE

060210

RATINGS AND PERFORMANCE

Firing Rate

1.50

Input (Btuh)

210,000

Heating Capacity (Btuh)*

170,000

AFUE %*

ICS

81.2

Oil Pump Stages

2

Heating Temp Rise

°

F

70—100

Recommended Heating Blower Speed

Medium

Cooling CFM @ 0.5-in. wc Static Pressure

2145

Heating CFM @ 0.2-in. wc Static Pressure

2125

ELECTRICAL

Unit Volts—Hertz—Phase

115—60—1

Operating Voltage Range†

104—127

Rated Load Amps

16.15

Minimum Ampacity for Wire Sizing

19

Minimum Wire Size AWG

12

Maximum Wire Length (Ft)‡

30

Maximum Fuse Size (Amps)**

20

Control Transformer (24v)

40va

External Control Power Available

Heating

35va

Cooling

35va

Burner Model (3450 RPM)

Beckett AFG

BLOWER DATA

Motor HP

3/4

Blower Wheel Size (In.)

12 x 12

Blower Motor Speed and Type

1075 PSC Direct

Filter Quantity and Size

(1) 24-1/2 x 38-1/4 x 1