Dimensions—model 362aan, Dimensions (in.), Minimum clearances to combustible materials (in.) – Bryant Oil Fired 363AAP 361AAN User Manual
Page 5: Air delivery—cfm (without filters)

—5—
DIMENSIONS—MODEL 362AAN
A96309
DIMENSIONS (In.)
*Flue pipe may be reduced to 5-in. diameter on 105 and 125 sizes for vent sizing.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (In.)
* Floor may be combustible.
AIR DELIVERY—CFM (Without Filters)
UNIT
SIZE
SHIP.
WT (Lb)
UNIT DIMENSIONS
DUCT SUPPLY OPENING
FLUE
DIAMETER
RETURN DUCT
WIDTH
DEPTH
HEIGHT
A
B
C
D
E
F
G
H
036105
248
22
52
33
20
17-1/4
6*
20
18
048125
269
22
57
33
20
22-1/4
6*
20
18
060155
278
22
57
33
20
22-1/4
6
*
20
18
UNIT APPLICATION
LOW-BOY
SIDES—Furnace
0
Supply Plenum and Warm-Air Duct Within 6 ft of Furnace
1
BACK
0
TOP— Furnace Casing or Plenum
2
Horizontal Warm-Air Duct Within 6 ft of Furnace
2
BOTTOM
0*
FLUE PIPE— Horizontally or Below Pipe
4
Vertically Above Pipe
8
FRONT
8
UNIT
SIZE
BLOWER
MOTOR
HP
SPEED
EXTERNAL STATIC PRESSURE IN. WC
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
036105
1/3 PSC
High
1795
1735
1675
1605
1550
1485
1425
1350
1275
1220
Medium
1365
1335
1305
1275
1255
1215
1155
1105
1050
985
Low
995
965
945
925
900
870
825
775
725
670
048125
1/2 PSC
High
1905
1845
1770
1695
1630
1565
1490
1425
1325
1220
Medium
1750
1675
1620
1560
1500
1440
1370
1305
1235
1130
Low
1390
1350
1305
1260
1220
1180
1120
1060
985
880
060155
3/4 PSC
High
2025
1960
1905
1850
1800
1655
1575
1500
1415
1315
Medium
1885
1825
1760
1705
1640
1565
1500
1430
1350
1265
Low
1555
1490
1445
1410
1350
1280
1230
1155
1085
1005
INSULATION
INTERMEDIATE
PANEL
FILTER
B
A
G
D
ELECTRICAL
CONNECTIONS
OIL INLET
F
12
1
⁄
16
″
E
H
1
″
INSULATION
PARTITION
PANEL
SUPPLY
DUCT
CLEAN-OUT PORTS
RETURN
DUCT
1
″
3
″
C