Combination ratings continued – Bryant QUANTUM PLUS 650A User Manual
Page 9
—9—
COMBINATION RATINGS Continued
* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard:
80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit.
High-Temp Heating Standard:
70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.
Low-Temp Heating Standard:
70°F (21°C) db indoor entering air temperature and 17°F (–9°C) db 15°F (–10°C) wb air entering outdoor unit.
† Outdoor section/indoor section combination tested in accordance with DOE test procedure for heat pumps.
‡ Based on computer simulation. TXV must be Puron compatible and hard shutoff type.
** In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance.
Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Bryant furnaces are equipped with TDR except for the
394HAD.
†† Indoor Airflow
COP
— Coefficient of Performance
EER
— Energy Efficiency Ratio
HSPF
— Heating Seasonal Performance Factor
SEER
— Seasonal Energy Efficiency Ratio
TC
— Total Capacity (Btuh)
TDR
— Time-Delay Relay
TXV
— Thermostatic Expansion Valve
UNIT
SIZE-
SERIES
INDOOR
UNIT
CFM††
ARI STANDARD RATINGS*
Cooling
Heating
TC
Seasonal Efficiency SEER
EER
High-Temp
Low-Temp
HSPF
Factory-
Supplied
Enhance-
ment
Standard
Rating
Field-Supplied
Accessory‡
Puron
TXV
Puron TXV
& TDR**
TC
COP
TC
COP
048-A,C
CJ5A/CK5A/CK5BA060
1400
45,000
NONE
—
—
12.50
10.75
48,000
3.50
28,600
2.38
8.20
CJ5A/CK5A/CK5BN060
1400
45,500
NONE
—
—
13.00
10.90
48,500
3.52
28,600
2.38
8.25
CJ5A/CK5A/CK5BX060
1400
45,500
NONE
—
—
13.00
10.90
48,500
3.52
28,600
2.38
8.25
CK3BA060
1400
45,000
NONE
—
—
12.50
10.75
48,000
3.50
28,600
2.38
8.20
060-B,C
FV4ANB006†
1750
58,000
TDR&TXV
13.00
—
—
10.75
60,000
3.56
37,000
2.54
8.00
FB4ANB070
1750
57,000
TDR
—
12.00
—
10.20
60,000
3.44
37,800
2.46
7.80
FC4BNB070
1750
57,000
TDR
—
12.00
—
10.20
60,000
3.44
37,800
2.46
7.80
FK4CNB006
1750
58,000
TDR
—
12.80
—
10.75
59,500
3.56
37,000
2.54
8.00
FX4ANB060
1750
57,000
TDR&TXV
12.00
—
—
10.20
60,000
3.44
37,800
2.46
7.80
CC5A/CD5AW060
1750
56,000
NONE
—
—
12.50
10.45
58,500
3.26
36,800
2.42
7.50
CJ5A/CK5A/CK5BX060
1750
56,500
NONE
—
—
12.50
10.55
59,000
3.44
37,000
2.50
7.70