Heat pump heating performance continued – Bryant QUANTUM PLUS 650A User Manual
Page 16
![background image](/manuals/52269/16/background.png)
—16—
HEAT PUMP HEATING PERFORMANCE Continued
See notes on page 17.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
–3
7
17
27
37
47
57
67
EDB
CFM
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Capacity
MBtuh†
Total
Pwr
Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw†
650AN036-A,C Outdoor Section With FX4ANF042 Indoor Section
65
1125
14.7 13.5 2.42 18.3 16.8 2.51 21.9 20.0 2.59 25.8 22.9 2.66 30.4 27.6 2.76 35.6 35.6 2.88 41.7 41.7 3.04 48.8 48.8 3.27
1250
14.9 13.7 2.45 18.5 17.0 2.53 22.9 20.9 2.61 26.1 23.2 2.67 30.7 27.9 2.76 35.9 35.9 2.87 42.1 42.1 3.03 49.3 49.3 3.25
1375
15.1 13.9 2.49 18.7 17.2 2.56 22.4 20.4 2.62 26.3 23.4 2.68 31.0 28.2 2.76 36.3 36.3 2.87 42.5 42.5 3.03 49.7 49.7 3.25
70
1125
14.1 13.0 2.51 17.9 16.4 2.61 21.6 19.7 2.70 25.4 22.6 2.79 29.9 27.2 2.89 35.0 35.0 3.02 41.5 41.5 3.19 48.0 48.0 3.42
1250
14.4 13.2 2.54 18.1 16.7 2.63 21.9 19.9 2.72 25.7 22.8 2.79 30.2 27.5 2.89 35.4 35.4 3.00 41.5 41.5 3.17 48.5 48.5 3.40
1375
14.6 13.4 2.58 18.4 16.9 2.66 22.1 20.1 2.74 26.0 23.1 2.81 30.5 27.8 2.89 35.7 35.7 3.00 41.8 41.8 3.16 48.9 48.9 3.39
75
1125
13.5 12.4 2.60 17.4 16.0 2.71 21.2 19.4 2.82 25.0 22.2 2.92 29.5 26.8 3.03 34.5 34.5 3.16 40.3 40.3 3.34 47.1 47.1 3.58
1250
13.8 12.7 2.63 17.7 16.2 2.74 21.5 19.6 2.84 25.3 22.5 2.92 29.8 27.1 3.02 34.8 34.8 3.15 40.8 40.8 3.31 47.7 47.7 3.55
1375
14.0 12.9 2.67 17.9 16.4 2.76 21.7 19.8 2.86 25.6 22.7 2.93 30.1 27.4 3.03 35.2 35.2 3.15 41.2 41.2 3.31 48.1 48.1 3.54
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Cooling
Indoor
Section
Size
Cooling
Capacity
Power
Capacity
Power
FX4ANF
042
1.00
1.00
CJ5A/CK5A/CK5BA
042
0.98
1.02
F(A,B)4AN(F,B,C)
042
0.98
1.02
048
0.98
1.01
FC4BN(F,B)
042
0.98
1.02
CJ5A/CK5A/CK5BN
042
0.98
1.02
FK4CNF
003
0.96
0.96
048
0.98
1.01
005
0.97
0.89
CJ5A/CK5A/CK5BW
048
0.98
1.01
FV4ANF
003
0.96
0.95
CK3BA
042
0.98
1.02
005
0.97
0.89
048
0.98
1.01
CE3AA
042
0.98
1.02
—
—
—
048
0.98
1.01
650AN042-A,C Outdoor Section With FV4ANF003 Indoor Section
65
1225
17.3 15.9 2.61 21.5 19.8 2.74 25.7 23.4 2.86 30.0 26.6 2.99 35.1 32.0 3.14 41.1 41.1 3.34 40.4 40.4 3.30 39.5 39.5 3.21
1400
17.6 16.2 2.61 22.5 20.7 2.74 25.9 23.6 2.84 30.2 26.9 2.95 35.5 32.3 3.09 41.5 41.5 3.28 40.8 40.8 3.22 40.0 40.0 3.14
1575
17.8 16.4 2.62 21.9 20.2 2.73 26.1 23.8 2.83 30.5 27.1 2.93 35.8 32.6 3.06 41.9 41.9 3.24 41.2 41.2 3.18 40.4 40.4 3.09
70
1225
16.8 15.5 2.74 21.1 19.4 2.88 25.4 23.2 3.03 29.6 26.3 3.16 34.7 31.6 3.32 40.5 40.5 3.53 39.8 39.8 3.48 38.9 38.9 3.38
1400
17.1 15.7 2.75 21.4 19.6 2.87 25.6 23.4 3.00 29.9 26.6 3.12 35.0 31.9 3.27 41.0 41.0 3.46 40.2 40.2 3.40 39.4 39.4 3.30
1575
17.3 15.9 2.76 21.6 19.8 2.87 25.8 23.6 2.99 30.1 26.8 3.10 35.3 32.2 3.24 41.3 41.3 3.42 40.6 40.6 3.35 39.8 39.8 3.25
75
1225
16.3 15.0 2.88 20.6 19.0 3.02 25.1 22.9 3.19 29.3 26.0 3.34 34.3 31.2 3.51 40.0 40.0 3.73 39.2 39.2 3.66 38.3 38.3 3.56
1400
16.6 15.2 2.89 20.9 19.2 3.01 25.3 23.1 3.17 29.6 26.3 3.30 34.6 31.5 3.46 40.4 40.4 3.66 39.6 39.6 3.58 38.8 38.8 3.47
1575
16.8 15.4 2.90 21.2 19.4 3.01 25.5 23.3 3.16 29.8 26.5 3.28 34.9 31.8 3.42 40.8 40.8 3.61 40.0 40.0 3.53 39.1 39.1 3.41
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Cooling
Indoor
Section
Size
Cooling
Capacity
Power
Capacity
Power
FV4ANF
003
1.00
1.00
FX4ANF
042
1.02
1.01
F(A,B)4AN(F,B,C)
048
1.02
1.03
CE3AA
048
1.02
1.04
FC4BN(F,B)
048
1.02
1.02
CJ5A/CK5A/CK5BA
048
1.02
1.03
FK4CNF
003
0.99
1.00
CJ5A/CK5A/CK5BN
048
1.02
1.03
005
0.99
0.93
CJ5A/CK5A/CK5BW
048
1.02
1.03
FV4ANF
005
0.99
0.93
CK3BA
048
1.02
1.03