beautypg.com

574d, Table 1—physical data con’t -- unit 574d – Bryant 574D User Manual

Page 7

background image

7

Table 1 – Physical Data -- Unit 574D

UNIT SIZE

018040

024040

024060

030040

030060

036060

036090

042060

042090

NOMINAL CAPACITY (ton)

1--- 1/2

2

2

2--- 1/2

2--- 1/2

3

3

3--- 1/2

3--- 1/2

OPERATING WEIGHT (lb)

OPERATING WEIGHT(kg)

282

127.9

296

134.2

296

134.2

313

142.0

313

142.0

338

153.3

338

153.3

401

181.9

401

181.9

COMPRESSORS

Quantity

Scroll

1

REFRIGERANT (R---410A)

Quantity (lb.)

Quantity (kg)

5.0

2.3

6.9

3.1

6.9

3.1

8.0

3.6

8.0

3.6

9.2

4.2

9.2

4.2

8.8

4.0

8.8

4.0

REFRIGERANT METERING DEVICE

TXV

CONDENSER COIL

Rows...Fins/in.

Face Area (sq ft)

1...21

10.2

2...21

10.2

2...21

10.2

2...21

11.9

2...21

11.9

2...21

13.6

2...21

13.6

2...21

19.4

2...21

19.4

CONDENSER FAN

Nominal Cfm

Diameter (in.)

Diameter (mm)

Motor Hp (Rpm)

2200

22

558.8

1/8 (825)

2200

22

558.8

1/8 (825)

2200

22

558.8

1/8 (825)

2800

22

558.8

1/8 (825)

2800

22

558.8

1/8 (825)

3000

22

558.8

1/8 (825)

3000

22

558.8

1/8 (825)

3500

22

558.8

1/8 (825)

3500

22

558.8

1/8 (825)

EVAPORATOR COIL

Rows...Fins/in.

Face Area (sq ft)

3...17

3.7

3...17

3.7

3...17

3.7

3...17

3.7

3...17

3.7

4...17

3.7

4...17

3.7

3...17

4.7

3...17

4.7

INDOOR BLOWER

Nominal Airflow (Cfm)

Size (in.)

Size (mm)

Motor HP (RPM)

650

10x10

254x254

1/4 (825)

800

10x10

254x254

1/3 (1050)

800

10x10

254x254

1/3 (1050)

1000

10x10

254x254

1/3 (1050)

1000

10x10

254x254

1/3 (1050)

1200

10x10

254x254

1/2 (1000)

1200

10x10

254x254

1/2 (1000)

1400

11x10

279.4x254

1/2 (1075)

1400

11x10

279.4x254

1/2 (1075)

FURNACE SECTION*

Burner Orifice No.

(Qty...Drill Size)

Natural Gas

Propane Gas

2...44

2...50

2...44

2...50

2...38

2...46

2...44

2...50

2...38

2...46

2...38

2...46

3...38

3...46

2...38

2...46

2...38

2...46

HIGH--PRESSURE SWITCH

(psig) Cut--out Reset (Auto)

650 +/-- 15

420 +/-- 25

LOSS--OF--CHARGE / LOW--PRES-

SURE SWITCH (Liquid Line) (psig)

cut--out Reset (auto)

20 +/-- 5

45 +/-- 10

RETURN---AIR FILTERS (in.)†}

Throwaway

20x24x1

508x610x25 (mm)

24x30x1

610x762x25 (mm)

24x36x1

610x914x25 (mm)

Table 1—Physical Data Con’t -- Unit 574D

UNIT SIZE

048090

048115

048130

060090

060115

060130

NOMINAL CAPACITY (ton)

4

4

4

5

5

5

OPERATING WEIGHT (lb)

OPERATING WEIGHT (kg)

418

189.6

418

189.6

418

189.6

446

202.3

446

202.3

446

202.3

COMPRESSORS

Quantity

Scroll

1

REFRIGERANT (R--410A)

Quantity (lb.)

Quantity (kg)

9.0

4.1

9.0

4.1

9.0

4.1

10.5

4.8

10.5

4.8

10.5

4.8

REFRIGERANT METERING DEVICE

TXV

CONDENSER COIL

Rows...Fins/in.

Face Area (sq ft)

2...21

19.4

2...21

19.4

2...21

19.4

2...21

19.4

2...21

19.4

2...21

19.4

CONDENSER FAN

Nominal Cfm

Diameter (in.)

Diameter (mm)

Motor Hp (Rpm)

3500

22

558.8

1/4 (1100)

3500

22

558.8

1/4 (1100)

3500

22

558.8

1/4 (1100)

4200

22

558.8

1/4 (1100)

4200

22

558.8

1/4 (1100)

4200

22

558.8

1/4 (1100)

EVAPORATOR COIL

Rows...Fins/in.

Face Area (sq ft)

3...17

5.7

3...17

5.7

3...17

5.7

4...17

5.7

4...17

5.7

4...17

5.7

INDOOR BLOWER

Max

Size (In.)

Size (mm)

Motor HP (RPM)

1600

1600

1600

2000

2000

1600

11x10

279.4x254

1/2 (1075)

1600

11x10

279.4x254

1/2 (1075)

1600

11x10

279.4x254

1/2 (1075)

2000

11x10

279.4x254

1.0 (1040)

2000

11x10

279.4x254

1.0 (1040)

2000

11x10

279.4x254

1.0 (1040)

FURNACE SECTION*

Burner Orifice No. (Qty...Drill Size)

Natural Gas

Propane Gas

3...38

3...46

3...33

3...42

3...31

3...41

3...38

3...46

3...33

3...42

3...31

3...41

HIGH--PRESSURE SWITCH

(psig) Cut--out Reset (Auto)

650 +/-- 15

420 +/-- 25

LOSS--OF--CHARGE / LOW--PRESSURE

SWITCH (Liquid Line) (psig) cut--out Reset

(auto)

20 +/-- 5

45 +/-- 10

RETURN--AIR FILTERS (in.)†}

Throwaway

24x36x1

610x914x25 (mm)

*Based on altitude of 0 to 2000 ft.
{

Required filter sizes shown are based on the larger of the ARI (Air Conditioning and Refrigeration Institute) rated cooling airflow or the heating airflow velocity

of 300 ft/minute for throwaway type or 450 ft/minute for high---capacity type. Air filter pressure drop for non---standard filters must not exceed 0.08 in. wc.

}

If using accessory filter rack refer to the filter rack installation instructions for correct filter sizes and quantity.

574D