4.4 Operation

Once the Converter is properly installed, it should operate transparently—

as if it were a standard cable connection. Operating power is derived from

the RS-232 data and control signals; there is no ON/OFF switch. All

data

signals from the RS-232 and RS-485 interfaces are passed straight through.
Additionally, in DCE mode, a Transmitter ON signal received at the

RS-422/485 RCV connection will cause DCD output at the RS-232

connector to assert HIGH. In DTE mode, a Transmitter ON signal at the

RS-422/485 RCV connection causes RTS output at the RS-232 connector to

go HIGH. Therefore, one hardware signal in either DTE or DCE mode is

virtually “passed through” the Converter in the direction of RS-422/485 IN

to RS-232 OUT.