DETAILED COOLING CAPACITIES* Continued

NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.

* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or

indoor unit is located above outdoor unit, a slight variation in capacity may occur.

† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh

(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air
per degree above 80°F (27°C). When the required data falls between the published data, interpolation may be performed.

** Total system kW is total of indoor and outdoor unit kilowatts.

†† At TVA rating indoor condition (75°F edb/63°F ewb). All other indoor air temperatures are at 80°F edb.

EVAP

AIR

CONDENSER ENTERING AIR TEMPERATURES °F

75

85

95

105

115

125

CFM

EWB

Capacity

MBtuh†

Total

Sys

kW**

Capacity

MBtuh†

Total

Sys

kW**

Capacity

MBtuh†

Total

Sys

kW**

Capacity

MBtuh†

Total

Sys

kW**

Capacity

MBtuh†

Total

Sys

kW**

Capacity

MBtuh†

Total

Sys

kW**

Total Sens‡

Total Sens‡

Total Sens‡

Total Sens‡

Total Sens‡

Total Sens‡

550A060-H Outdoor Section With CD5PX060 Indoor Section

1750

57

57.89

57.89

4.31

55.67

55.67

4.76

53.35

53.35

5.27

50.80

50.80

5.83

47.87

47.87

6.43

44.52

44.52

7.08

62

59.84

53.84

4.33

57.09

52.53

4.78

54.23

51.17

5.28

51.12

49.67

5.84

47.85

47.85

6.43

44.51

44.51

7.08

67

65.37

45.55

4.39

62.27

44.22

4.84

59.00

42.86

5.34

55.44

41.38

5.89

51.48

39.77

6.47

47.02

37.98

7.11

72

71.38

37.24

4.45

67.95

35.91

4.91

64.32

34.50

5.41

60.36

33.01

5.96

55.94

31.39

6.53

50.98

29.58

7.15

2000

57

60.22

60.22

4.42

57.88

57.88

4.89

55.28

55.28

5.39

52.49

52.49

5.95

49.40

49.40

6.55

45.73

45.73

7.19

62

61.19

57.67

4.44

58.34

56.29

4.89

55.34

54.77

5.39

52.48

52.48

5.95

49.40

49.40

6.55

45.71

45.71

7.19

67

66.60

48.31

4.49

63.37

46.97

4.96

59.86

45.53

5.45

56.10

44.02

5.99

52.03

42.39

6.58

47.43

40.59

7.21

72

72.67

38.92

4.56

69.11

37.58

5.02

65.22

36.14

5.52

61.05

34.63

6.06

56.50

32.98

6.63

51.36

31.14

7.25

2250

57

62.16

62.16

4.54

59.57

59.57

5.00

56.86

56.86

5.50

53.93

53.93

6.06

50.56

50.56

6.65

46.69

46.69

7.29

62

62.34

61.20

4.54

59.51

59.51

5.00

56.85

56.85

5.50

53.92

53.92

6.06

50.55

50.55

6.65

46.69

46.69

7.29

67

67.52

50.93

4.60

64.07

49.53

5.06

60.43

48.08

5.55

56.59

46.55

6.09

52.42

44.91

6.67

47.72

43.08

7.31

72

73.65

40.55

4.67

69.86

39.16

5.13

65.83

37.69

5.62

61.56

36.15

6.16

56.87

34.48

6.73

51.61

32.64

7.35

Multipliers for Determining the Performance With Other Indoor Sections

Indoor

Section

Size

Cooling

Indoor

Section

Size

Cooling

Capacity

Power

Capacity

Power

CC5A/CD5AA

060

0.95

0.98

CK5A/CK5BT

060

0.97

0.96

CC5A/CD5AW

060

0.98

1.00

CK5A/CK5BX

060

0.99

0.96

CD5PX

060

1.00

1.00

CK5PA

060

0.97

0.96

CE3AA

060

0.98

0.99

CK5PT

060

0.97

0.96

CK3BA

060

0.98

0.99

CK5PX

060

0.99

0.96

CK5A/CK5BA

060

0.98

0.99

COILS + 315(A,J)AV066155 VARIABLE SPEED FURNACE

CK5A/CK5BT

060

0.98

0.99

CC5A/CD5AA

060

0.95

0.95

CK5A/CK5BX

060

1.00

0.99

CD5PX

060

0.98

0.95

CK5PA

060

0.98

0.99

CE3AA

060

0.98

0.95

CK5PT

060

0.98

0.99

CK3BA

060

0.97

0.95

CK5PX

060

1.00

0.99

CK5A/CK5BA

060

0.97

0.95

F(A,B)4BN(F,B,C)

060

0.98

1.01

CK5A/CK5BT

060

0.97

0.95

FB4BNB

070

1.00

1.00

CK5A/CK5BX

060

0.99

0.95

FC4CN(F,B)

060

0.98

1.01

CK5PA

060

0.97

0.95

FC4CNB

070

1.00

1.00

CK5PT

060

0.97

0.95

FE4ANB

006

1.00

0.94

CK5PX

060

0.99

0.95

FG3AAA

060

0.97

0.99

COILS + 355MAV060080 VARIABLE SPEED FURNACE

FK4DNB

006

1.00

0.94

CK3BA

060

0.97

1.01

FV4BNB

006

1.00

0.94

CK5A/CK5BA

060

0.97

1.01

FX4BNB

060

1.00

1.00

CK5A/CK5BT

060

0.97

1.01

COILS + 315(A,J)AV060110 VARIABLE SPEED FURNACE

CK5PA

060

0.97

1.01

CC5A/CD5AA

060

0.95

0.98

CK5PT

060

0.97

1.01

CD5PX

060

0.98

0.98

COILS + 355MAV060100 VARIABLE SPEED FURNACE

CE3AA

060

0.98

0.98

CK3BA

060

0.97

1.00

CK3BA

060

0.97

0.97

CK5A/CK5BA

060

0.97

0.99

CK5A/CK5BA

060

0.97

0.97

CK5A/CK5BT

060

0.97

0.99

CK5A/CK5BT

060

0.97

0.97

CK5PA

060

0.97

0.99

CK5A/CK5BX

060

0.99

0.97

CK5PT

060

0.97

0.99

CK5PA

060

0.97

0.97

COILS + 355MAV060120 VARIABLE SPEED FURNACE

CK5PT

060

0.97

0.97

CC5A/CD5AA

060

0.95

0.99

CK5PX

060

0.99

0.97

CK3BA

060

0.97

0.99

COILS + 315(A,J)AV066135 VARIABLE SPEED FURNACE

CK5A/CK5BA

060

0.97

0.99

CC5A/CD5AA

060

0.95

0.96

CK5A/CK5BT

060

0.97

0.99

CD5PX

060

0.98

0.96

CK5A/CK5BX

060

0.99

0.99

CE3AA

060

0.98

0.96

CK5PA

060

0.97

0.99

CK3BA

060

0.97

0.96

CK5PT

060

0.97

0.99

CK5A/CK5BA

060

0.97

0.96

CK5PX

060

0.99

0.99