beautypg.com

General information, I: general information – Burnham HF SERIES User Manual

Page 5

background image

5

I: General Information

Figure 1: HF Packaged Boiler (HF-98/HF-173)

Notes:

1.

2.

3.

4.

5.

Firing rates based on 140,000 BTU per gallon of oil

IBR net water ratings based on a pick-up allowance of 1.15

Manufacturer should be consulted before selecting a boiler for installations having

unusual piping and pick-up requirements.

Firebox draft setting: -.02 inches water column

Ratings based on 13.0% CO

2

Ta ble 1 :

WAT ER RAT ING S AN D S PEC IFI C ATI O NS

Descr iption

HF- 98

HF- 122

HF- 147

HF- 173

DO E Heating Capac ity ( MB H)

104

132

154

184

IBR Net Water rating ( MB H)

90

115

134

160

Fir ing Ra te (gal/hr )

.85

1.10

1.25

1.50

Noz zle Spec ifi cation

.75 x 45° B

.90 x 45° B

1.00 x 45° B

1.25 x 45° B

Stac k Dia meter (inc h)

6

6

7

7

Nu mber of Tub es

12

12

18

18

Boiler Water Cap. ( gal.)

20

20

40

40

Supply S ize ( FPT)

2

2

Retur n S ize ( FPT)

2

2

Tankles s Heater S ize (gal/mi n)

4 (5 Optiona l)

4 (5 Optiona l)

5

5

Chimn ey S ize (mi n)

8" x 8" x 15'

8" x 8" x 15'

8" x 8" x 15'

8" x 8" x 15'

Appr ox. S hipping Wt. ( lb.)

450

450

720

720

DIM ENSIO N S M ax . W orki ng P re s su re : 30 PSI (W ate r O nly)

A Over all W idth ( in.)

18-1/8

18-1/8

24

24

B Over all Len gth Boiler ( in.)

24-1/2

24-1/2

31-3/4

31-3/4

C J ack et Height ( in.)

37-3/4

37-3/4

46-3/4

46-3/4

D J ack et Length ( in.)

18

18

21-3/4

21-3/4

E Jac ket W idth ( in.)

18-1/8

18-1/8

22

22

F S mok e Outlet Height ( in.)

25-1/4

25-1/4

30

30

G O ver all Leng th w/Burner ( in.)

33

33

39

39