Toshiba Magnia 3100 User Manual
Page 72
![background image](/manuals/489043/72/background.png)
64
HW Diagnostics
Log Utilities
Log Utilities
This function logs error information generated while a test is in progress; it shows the results stored in
RAM.
The error logs can be checked by selecting [03. LOG UTILITIES] in the main menu.
Selecting [01.LOG UTILITIES] shows the following message:
LOG UTILITIES Screen
XXXXX ERRORS
The message shows the number of errors.
PASS COUNT
If the test parameter "Test Loop" is set as "Yes" in the test, the pass count is displayed.
CNT
It shows the number assigned, according to the order of occurrence of the errors.
TEST
XXX XX XX
digits 1-3 :
It shows the abbreviation of the test in which the error occurred.
MEMORY TEST
RAM
NPX TEST
NPX
KEYBOARD TEST
KBD
CACHE MEMORY TEST
CAH
DISPLAY TEST
CRT
SCSI TEST
SCS
FLOPPY DISK TEST
FDD
CD-ROM TEST
CDR
PRINTER TEST
PRT
SAF-TE TEST
SAF
SCSI HDD TEST
HDD
BMC TEST
BMC
digits 4-5:
It shows the subtest number in which the error occurred.
digits 6-7:
It shows the step number in which the error occurred. (Depending on the
test, Digits 6-7 are not always displayed.)