Toshiba Magnia 3100 User Manual
Page 67

59
HW Diagnostics
NPX TEST
AA BB CC DD EEEE FFFF
AA
:
Host number that the hard disk drive is connected, and Channel number
BB
: Driver completion status
CC
: ASPI status
DD
: Host
status
EEEE :
Sense data
FFFF
: Sense code
[07. NPX TEST]
This tests the computer's floating data processing unit functions.
[01. NPX test]
This test checks the Addition and Multiplication functions of the coprocessor.
NPX TEST (NPX) Error log
Status Error
name
Meaning
01
NO CO-PROCESSOR
Co-processor recognition error
02
CONTROL WORD ERROR
Control word error
03
STATUS WORD ERROR
Status word error
04
BUS ERROR
BUS error
05
ADDITION ERROR
Addition test error
06
MULTIPLICATION ERROR
Multiplication test error
07 EXCEPTION
ERROR
Exception
error
[08. CACHE MEMORY TEST]
To test the L2 caching unit.
[01. Constant data test]
After the read (to hit) of all cache memory, the constant data are written, read and compared.
[02. Address Pattern test]
After the read (to hit) of all cache memory, the address pattern data are written, read and
compared.
[03. Increment/Decrement test]
After the read (to hit) of all cache memory, the increment and decrement data are written, read
and compared.
[04. Caching data test]
This test checks caching and the cache controller.
CACHE MEMORY TEST (CAH) Error log
Status Error
name
Meaning
01
MEMORY PARITY ERROR
Memory parity error
02
PROTECT MODE ERROR
The shift to the protected mode failed.
03
CACHING ERROR
An error occurred on the cache system.
FF
DATA COMPARE ERROR
Data comparing error