Three red LED indicators are located on top of the 485DSS.
The LED labeled TD flashes when the RS-232 device is transmitting
data. The LED labeled RD flashes when data is being received by
the 485DSS from the RS-485 network. The LED labeled SEL turns
on indicating that the RS-232 device has access to the RS-485
network. Refer to Figure 2. Terminal blocks on the 485DSS
connect the RS-485 signals, and input power to the unit. The RS-
232 DTE signals of the 485DSS connect to a DB25 male connector.
An eight-position switch located in the top center of the 485DSS sets
the 485DSS's unique address.
Communication Configuration
Before the HOST can communicate with a 485DSS, the
HOST must set its communication format to: 9600 baud, 8 data bits,
no parity, and 1 stop bit. After communicating with the 485DSS, the
HOST can reset its communication format to match the format of the
RS-232 device attached to the 485DSS. ALL data is passed through
the unit after it has been selected. The 485DSS does not have any
buffering.
Distributed Smart Switch Commands
The 485DSS constantly monitors the serial data received on the
RS-485/422 port for a command string. There are only three
commands required to control the 485DSS: the ON command, the
OFF command, and the status request command.
Figure 5. Simplified Functional Diagram