If necessary, set the serial interface parameters as follow:

1. Make sure that the printer is in the off-line state.

2. Set the serial interface parameters by moving up (on) or down (off)

the selectors of the dual in-line package (DIP) switch.

ON

1 2 3 4 5 6 7 8

Fig. 4-2 Setting the Serial Interface Parameters

Table 1: Serial Interface Parameters Settings

Selector

Parameters

On (up)

Off (down)

1

Baud Rate

See Table 2. —

2

Baud Rate

See Table 2. —

3

Data Length

7 bits

8 bits

4

Stop Bit

2 bits

1 bit

5

Parity

See Table 3. —

6

Parity

See Table 3. —

7

Protocol

Xon/Xoff + DTR

DTR only

8

Robust Xon

On

Off

Table 2: Baud Rate Settings

Selector 1

Selector 2

For RS-422A

For RS-232C

Off

Off

57600

9600

On

Off

9600

4800

Off

On

1200

1200

On

On

19200

19200