Troubleshooting

Problem

IR side burner will not
stay lit

IR side burner will not
light using ignitor or
match

Burners will not light
using a match

Low flame or low heat

Possible Cause

Regulator coupling nut is not
fully connected to LP cylinder

LP-Excess flow valve tripped in
regulator

Vapor lock in connections

Obstructions in Burners

Wet Electrodes and Burners

Wire loose or disconnected

Wire shorting (sparking
between Igniter and Electrode)

Thermocouple is not properly
attached to side burner valve.
Safety sensor is not completely
heated

IR side Burner has filled with
water

Burners not assembled correctly

LP Gas Cylinder is empty

LP-Excess flow valve tripped in
regulator

Regulator Coupling nut is
not fully connected to LP Gas
Cylinder

Obstructions in Burners

LP-gas in LP Gas Cylinder is low

Excess flow valve tripped in
regulator

Solution

Tighten coupling nut by hand about one-half to three quar-
ters additional turn. Do not use tools.

Turn Control Knobs to “Off” position and turn LP Gas Cyl-
inder handle clockwise until it stops. Wait five minutes. Relight
LP gas grill. If flame continues to be low, turn off gas at LP Gas
Cylinder and grill. Disconnect the regulator from the LP Gas
Cylinder. Reconnect the regulator to the LP Gas Cylinder. This
will reset the excess flow valve Perform a leak test. Relight grill.

Clean the Burners. See “How to Clean Burners” in Care
and Maintenance.

Dry Electrode with clean cloth. Air dry or use blow dryer.

Reconnect the wire.

Replace Igniter Wire/Electrode assembly.
(Call the Customer Service Department)

See Step 14C Page 13

Follow lighting proceedure but hold control knob IN for at least
10 seconds.

Blow water out of ceramic center of burner.
Close lid when not in use.

See re-assembly after cleaning in Care and Maintenance.

Take LP Gas Cylinder to licensed LP gas supplier to be refilled.

Turn Control Knobs to “Off” position and turn LP Gas Cyl-
inder handle clockwise until it stops. Wait five minutes. Relight
LP gas grill. If flame continues to be low, turn off gas at LP Gas
Cylinder and grill. Disconnect the regulator from the LP Gas
Cylinder. Reconnect the regulator to the LP Gas Cylinder. This
will reset the excess flow valve Perform a leak test. Relight grill.

Tighten Regulator Coupling nut by hand about one-half to
three quarters additional turn. Do not use tools.

See “How to Clean Burners” in Care and Maintenance.

Check LP Gas Cylinder. Refill if necessary.

Turn Control Knobs to “Off” position and turn LP Gas Cyl-
inder handle clockwise until it stops. Wait five minutes. Relight
LP gas grill. If flame continues to be low, turn off gas at LP Gas
Cylinder and grill. Disconnect the regulator from the LP Gas
Cylinder. Reconnect the regulator to the LP Gas Cylinder. This
will reset the excess flow valve Perform a leak test. Relight grill.