beautypg.com

Solving problems with printing quality, Solving problems with printing quality 127 – Konica Minolta Magicolor 2550 User Manual

Page 141

background image

Solving Problems with Printing Quality

127

Solving Problems with Printing Quality

Symptom

Cause

Solution

Nothing is
printed, or
there are
blank spots
on the
printed page.

One or more of the
toner cartridges may
be defective.

Remove the toner cartridges and
check if any is damaged.

The drum cartridge
may be defective.

Remove the drum cartridge and check
for damage. If it is damaged, replace it.

The media is moist
from humidity.

Adjust the humidity for media storage.
Remove the moist media and replace it
with new, dry media.

The media set in the
printer driver mis-
matches the media
loaded in the printer.

Load the correct media in the printer.

The power source
does not match the
printer specifications.

Use a power source with the proper
specifications.

Several sheets are
being fed at the same
time.

Remove the media from the tray and
check for static electricity. Fan plain
paper or other media (but not transpar-
encies), and replace it in the tray.

Media is not set prop-
erly in the tray(s).

Remove the media, tap it to straighten
it out, return it into the tray, and realign
the media guides.

Entire sheet
is printed in
black or
color.

One or more of the
toner cartridges may
be defective.

Remove the toner cartridges and
check each for damage. If one or more
is damaged, replace it.

The drum cartridge
may be defective.

Remove the drum cartridge and check
for damage. If it is damaged, replace it.

This manual is related to the following products: