beautypg.com

2 preventing unauthorized access – Konica Minolta bizhub 652 User Manual

Page 19

background image

bizhub 652/602/552/502

2-6

2.2

Preventing Unauthorized Access

2

2.2

Preventing Unauthorized Access

When access to the machine by the Administrator of the machine through the Administrator Settings is au-
thenticated, the machine enables setting of the operation of Prohibited Functions When Authentication Error.
The machine then takes a count of the number of unsuccessful accesses to the Administrator Settings to
prohibit the authentication operation.

Either [Mode 1] or [Mode 2] can be selected for Prohibited Functions When Authentication Error. The factory
setting is [Mode 1]. If [Mode 2] is set, the check count can be selected from among once to five times. To
prevent unauthorized access, operate the machine in [Mode 2].
If [Mode 2] is selected, the Release Time Settings function is enabled. When the Administrator Settings is set
into the access lock state, the main power switch is turned off and on and, after the lapse of a predetermined
period of time after the machine is turned on again, the access lock state of the Administrator Settings is can-
celed. The Release Time Settings function allows the period of time, after the lapse of which the access lock
state of the Administrator Settings is canceled, to be set in the range between 1 and 60 min. The factory set-
ting is 5 min. For details of each mode, see the table below.

NOTICE

If the access lock state of the Administrator Settings is canceled by the Service Engineer, the setting of the
Release Time Settings function is not applied.

Setting Prohibited Functions When Authentication Error

0

For the procedure to call the Administrator Settings screen on the display, see page 2-2.

0

Do not leave the machine with the setting screen of Administrator Settings left shown on the display. If
it is absolutely necessary to leave the machine, be sure first to log off from the Administrator Settings.

1

Call the Administrator Settings screen on the display from the control panel.

2

Touch [Security Settings].

Mode

Description

Mode 1

If authentication fails, the authentication operation (entry of the
password) is prohibited for 5 sec.

Mode 2

If authentication fails, the authentication operation (entry of the
password) is prohibited for 5 sec. The number of times, in which
authentication fails, is also counted and, when the failure count
reaches a predetermined value, the authentication operation is
prohibited and the machine is set into an access lock state.

This manual is related to the following products: