Replacing Consumables

133

If

IMAGING UNIT LIFE

on the

SYS DEFAULT MENU

is set to

STOP

,

the message

I-UNIT LIFE X

(where “

X

”. represents the color of the

toner) appears when a imaging unit becomes empty. Follow the steps below
to replace the imaging unit.

"

If

IMAGING UNIT LIFE

on the

SYS DEFAULT MENU

menu is

set to

CONTINUE

, you are advised to replace the indicated imaging

unit when the message

I-UNIT END X

appears.

1

Check the message window to see which color imaging unit needs replac-
ing.

2

Open the printer’s front cover.

3

Press down the area marked
“Push” on the imaging unit to be
replaced, and then slide the unit
all the way out of the printer.

"

Dispose of the used imaging unit according to your local regula-
tions.
Do not burn the imaging unit.

4

Check the color of the new imaging unit to be installed.