Diagnostic Error Code
FRU/Action
020-197-XXX PCI test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 51.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
020-198-XXX PCI test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 51.
2. Flash the system and re-test. See “Flash update
3. Go to “Undetermined problems” on page 76.
020-199-XXX PCI test failed, cause unknown
1. Go to “Undetermined problems” on page 76.
2. Flash the system and re-test. See “Flash update
3. Replace component under function test.
020-262-XXXPCI system error
1. PCI card
2. Riser card, if installed.
3. System board
025-000-XXXIDE interface Test Passed
No action
025-00X-XXX 025-01X-XXX IDE interface failure
1. IDE signal cable
2. Check power supply voltages.
3. Reseat IDE signal cable.
4. IDE device
5. System board
025-027-XXX IDE interface Configuration/Setup error
1. IDE signal cable
2. Flash the system. See “Flash update procedures”
3. Reseat IDE signal cable.
4. IDE device
5. System board
025-02X-XXX 025-03X-XXX 025-04X-XXX IDE Interface
failure
1. IDE signal cable
2. Check power supply.
3. Reseat IDE signal cable.
4. IDE device
5. System board
025-195-XXX IDE interface Test aborted by user
Information only Restart the test, if necessary.
025-196-XXX IDE interface test halt, error threshold
exceeded
1. Press F3 to review the log file.
2. Restart the test to reset the log file.