Volts command, Description, Example – Lenovo ThinkServer TD200 User Manual
Page 86: Vpd command, Syntax

CPU2
58/14
72/22
80/27
85/29
9/320
DASD1
66/19
73/23
82/28
88/31
9/332
Amb
59/15
70/21
83/28
90/32
9/355
system>
Notes:
1.
The output has the following column headings:
WR: warning reset
W: warning
T: temperature (current value)
SS: soft shutdown
HS: hard shutdown
2.
All temperature values are in degrees Fahrenheit/Celsius.
volts command
Description
Use the volts command to display all the voltages and voltage thresholds. The
same set of voltages are displayed as in the Web interface.
Example
system> volts
HSL
SSL
WL
WRL
V
WRH
WH
SSH
HSH
----------------------------------------------------------
5v
5.02
4.00
4.15
4.50
4.60
5.25
5.50
5.75
6.00
3.3v
3.35
2.80
2.95
3.05
3.10
3.50
3.65
3.70
3.85
12v
12.25 11.10 11.30 11.50 11.85 12.15 12.25 12.40 12.65
-5v
-5.10 -5.85 -5.65 -5.40 -5.20 -4.85 -4.65 -4.40 -4.20
-3.3v -3.35 -4.10 -3.95 -3.65 -3.50 -3.10 -2.95 -2.80 -2.70
VRM1
3.45
VRM2
5.45
system>
Note:
The output has the following column headings:
HSL: hard shutdown low
SSL: soft shutdown low
WL: warning low
WRL: warning reset low
V: voltage (current value)
WRH: warning reset high
WH: warning high
SSH: soft shutdown high
HSH: hard shutdown high
vpd command
Syntax
vpd sys
vpd IMM
vpd biosvpd dsa
Description
Use the vpd command to display vital product data for the system (sys), IMM,
server firmware (bios), and Dynamic System Analysis Preboot (dsa). The same
information is displayed as in the Web interface.
80