beautypg.com

Vollrath F111 User Manual

Page 24

background image

Owner’s Manual #513632-5 Rev.1

18

E111I/F111I Model Machines

Up Time (hours)

This value is a record of the total time the machine
has been in service. If power is interrupted, the
timer will stop until power is restored. This timer
does not reset.

RUN STATISTICS

In addition to dynamic readings and recorded
error code details, the IntelliTec control records
rolling averages of run statistics. Following are the
readings available under the RUNSTATS menu:

On Times (sec)

The control records the time of each freezing
cycle and provides a rolling average.

Off Times (sec)

The control records the time between freezing
cycles and provides a rolling average.

Brl. Min (°F)

The lowest average barrel temperature is
recorded.

Brl. Max (°F)

The highest average barrel temperature is
recorded.

Stor Min (°F)

The lowest average hopper temperature is
recorded.

Stor Max (°F)

The highest average hopper temperature is
recorded.

Power On (hrs)

This value is a record of the time the machine
has been in service. If power is interrupted, the
timer will reset.

4.6

ADJUSTMENTS (SERVICE PERSONNEL

ONLY)

The following adjustments directly affect product consis-
tency and length of time in “Serve Mode”. The default
settings have been created using a 5% milkfat soft serve
mix and provide optimal product consistency while pro-
longing product life.

CutOut (amps)

It is recommended to change the CutOut value
at initial startup and when changing mix types.
Adjustments to this setting directly affect the
length of the freezing cycle which changes product
consistency. To properly set the CutOut value,
refer to Section 3.

Cut In T (°F)

After the consistency value has been determined,
the Cut In T value can be adjusted. The Cut In
T is the temperature of the refrigerant gas in the
evaporator. Changing this setting changes the
temperature at which the freezing cycle starts. This
value along with the CutOut value determines the
range of temperatures (or “temperature window”)
of the product. Decreasing the temperature
decreases the temperature window and, under
normal use, increases the amount of freezing
cycles. This creates a greater chance of product
breakdown by stirring the product often. Increasing
the Cut In T increases the temperature window
which decreases freezing cycles and increases
the chance of heat shock within the product.

Cycles (count)

This setting determines the number of freezing
cycles during “Serve Mode”. Increasing the value
will increase the total time in “Serve Mode”. Factory
default is 16 cycles. This results in “Serve Mode”
lasting about 2 to 2-1/2 hours without the PUSH
TO FREEZE button being pressed or a spigot
handle being pulled. If the PUSH TO FREEZE
button is pressed or the spigot handle is pulled at
any time during “Serve Mode”, the Cycles count
will reset.

4.7

OTHER SETTINGS (SERVICE

PERSONNEL ONLY)

Changing any setting on the IntelliTec control will alter
machine operation and affect the product temperature,
consistency, or life. Refer to the IntelliTec Control System
Settings sheet located in the information pouch behind
the header panel of the machine. If any of the following
settings on the IntelliTec control differ from the System
Settings sheet, it is recommended to revert those settings
to factory defaults.

Stir On (sec)

Adjustments to this setting affect the amount of
time the auger rotates in the stir cycle. The stir
cycle occurs in “Serve Mode”, “Standby Mode”,
and “Sleep 2 Mode”.

Stir Off (sec)

Adjustments to this setting affect the time between
stir cycles. The stir cycle occurs in “Serve Mode”,
“Standby Mode”, and “Sleep 2 Mode”.

On Time (sec)

Increasing this value will increase the length of the
freezing cycle during “Standby Mode” and result
in a decrease of average product temperature in
the barrel.

This manual is related to the following products: