E111I/F111I Model Machines

Modifying Control Settings

To change the value of a system function, locate the
function on the IntelliTec Settings Menu and follow the
steps below.

IMPORTANT:

Before making changes to any settings, record
the original values. If the setting changes do not
achieve desired results, revert settings to their
original values.

A.

Press and hold SEL button for 8 seconds. While
still holding the SEL button, press the up arrow
button (

). The LCD Screen will read DISPLAY.

B.

Release both buttons.

C.

Press the left arrow button (

) to get to the correct

menu (Basic, Advanced, or Storage).

D.

Press the up arrow button (

) to navigate to the

value that needs to be changed.

E.

Press SET button to enter edit mode.

F.

Press the up arrow button (

) to change setting.

G.

Press SET button to save the setting and exit the
edit mode.

H.

Press the up arrow (

) and left arrow () buttons

to navigate through the rest of the settings as
needed.

I.

When all changes have been completed, press
the up arrow button (

) from ExitMenu to return

to the current mode display.

4.5

READINGS (SERVICE PERSONNEL

ONLY)

The IntelliTec control continuously monitors and records
temperatures, voltages, amps, and error code details.
Each of these readings are benefi cial to service personnel
when troubleshooting.

DISPLAY READINGS

Following are the readings available under the DISPLAY
menu:

Hopper (°F)

The temperature of the hopper is constantly
monitored by the IntelliTec control.

Cycles (count)

This reading counts down the number of cycles
in the current “Serve Mode”. The starting value
is dependant upon the Cycles setting on the
IntelliTec control.

°F and amps

The suction line temperature on the freezing
cylinder and the drive motor amps are available
on the same screen to assist with setup and
troubleshooting.

Aux. Temp (°F)

This reading provides the ambient temperature
around the IntelliTec control.

Supply V (VAC)

A calculated input voltage is recorded.

ERROR CODE READINGS

The following details are recorded under the ERRCODES
menu for each of the last 25 error codes received:

Err1 (hours)

A numerical count of the last 25 error codes is
recorded. When the 26th error has occurred
the earliest error code is erased. A timer also
begins when an error occurs. The timer records
the number of hours since the error occurred. If
power to the machine is interrupted, the timer will
stop until power has been restored.

°F and amps

The suction gas temperature on the freezing
cylinder and the drive motor amps are recorded
at the time of the error.

Aux. Temp (°F)

Ambient temperature of the IntelliTec control is
recorded at the time of the error.

Str (°F)

The storage temperature is recorded at the time
of the error.

VAC and Mode

A calculated input voltage and mode at which
the error occurred are recorded. Following are
descriptions of each mode:

Mode

Description

0

Start of freezing cycle

1

Compressor and drive motor on

2

Stir

Cycle

3

Compressor

off

4

“Standby

Mode”

5

“Sleep 1 Mode”

6

“Sleep 2 Mode”

7

“Clean

Mode”

8

Startup

9

Storage only refrigeration

10

Freezing cycle is shut down

11

Door safety switch triggered

12

High pressure cutout