Silent Call SD4-SS User Manual
Page 15

15
the detector to automatically maintain proper operation at factory 
calibrated detection levels, even when sensitivity is altered due to the 
presence of contaminants settling into the unit’s smoke chamber. In 
order for this feature to work properly, the chamber must never be 
opened while power is applied to the smoke detector. This includes 
cleaning, maintenance or screen replacement.
The Model #SD4-SS contains a piezoelectric horn which generates 
the ANSI S3.41 temporal pattern in an alarm condition. During an 
alarm condition, pressing the detector’s test switch will silence the 
piezoelectric horn for 5 minutes. The built-in Drift Compensation 
algorithm automatically maintains the sensitivity of the detector. 
The mounting base installation is simplified by the incorporation 
of features compatible with drywall fasteners or other methods that 
provide a method for securing the detector in place.
An indication that current studies have shown smoke alarms may not 
awaken all sleeping individuals, and that it is the responsibility of 
individuals in the household that are capable of assisting others to provide 
assistance to those who may not be awakened by the alarm sound, or to 
those who may be incapable of safely evacuating the area unassisted.