Norgren 5030 Series User Manual
Next generation solenoid valve 5030 series, Performance, Features

Performance
Application
Three-way normally open and normally closed solenoid operated air valve designed for continuous duty
under-hood, and chassis applications.
Operating Temperature
-40°F- 257°F (-40°C- 125°C)
Operating Voltage
9 to 16 volts
Drop Out Voltage
0.5 volts
Power
0.30 amps at 12 volts, 68° F
Resistance
40 Ohms ± 10% at 68°F
Pressure Rating
60 to 150 PSIG (4.14 to 10.34 bars)
Flow Rate
2.76 SCFM minimum at 120 PSIG (8.27 bars)
Equivalent Orifice
0.047 diameter (CV = 0.042)
Leakage
Less than 20 SCCM
Air Connections
Integral 1/4" push-to-connect fittings (meets SAE J2494-3, and FMVSS 571-106)
Electrical Connections
Male 150 series connector to mate with Packard electric metri-pack 150 sealed connector, part number
12052641.
Part Numbers
5030-111 (Three-way NC, PTC fittings), 5030-211
(Three-way NO, PTC fittings),
Mounting
One 5/16" or 8mm bolt.
Part Marking
Part labeled with part number and date code.
Features
Norgren GT Development has developed a family
of solenoid air valves specifically for severe-
duty, high-temperature applications up to 250°F
(125°C) continuous duty.
2007 EPA regulations required higher turbo
boost pressures creating a hotter overall
engine compartment. Cooling systems are
designed to dissipate as much of this heat as
possible. These valves anticipate the need for
more robust component parts on and around
the engine, targeting a particularly demanding
application, the fan clutch solenoid valve. These
valves, mounted in the engine compartment, are
continuously energized in most installations.
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
© Norgren GT Development Corporaton, 2014
Next Generation Solenoid Valve
5030 Series
Rev. 8/14
01