T72 Shut-off & Lockout Valves

Littleton, CO USA

Phone 303-794-2611

www.norgren.com

ALE-15-3

All Dimensions in Inches (mm)

Technical Data

Fluid: Compressed air
Maximum Pressure: 250 psig (17 bar)
Operating Temperature*: -30° to 150°F (-34° to 65°C)

* Air supply must be dry enough to avoid ice formation at temperatures below 35°F (2°C).

Cv factor from IN to OUT ports

1/4" ports: 4.0
3/8" ports: 8.0

Cv factor from OUT to EXHAUST ports on 3-port/2-position valves: 0.2.
Exhaust port threads on T72T models: 10-32
Hole diameter in slide for padlock: 5/16" (8 mm)
Materials

Body: Zinc
Slide: Acetal plastic
Elastomers: Nitrile

Service Kits

Item

Type

Part Number

Service kit

Actuator seals and slide

4384-513

Service kit includes actuator seals and slide.

1.97 (50)

1.89 (48)

3.46 (88)