Norgren V72G Series Datasheets User Manual
V72g
Littleton, CO USA
Phone 303-794-2611
www.norgren.com
V72G
●
Excelon design allows in-line or modular installation
●
Push to lock adjusting knob with tamper resistant
accessory
●
Helps protect air operated equipment from over
pressure by retarding excessive pressure build up
●
Modular installations with Excelon 72, 73, and 74
series can be made to suit particular applications
●
Relief port located on bottom allows easy installation
72 Series Pressure Relief
Valve 1/4", 3/8" Port Size
ALE-14-4
See Section ALE-24 for Accessories
Ordering Information.
Models listed include PTF threads, knob adjustment, and a 5 to 150 psig (0.3 to 10 bar) outlet pressure adjustment range*.
Port Size
Model
Weight lb (kg)
1/4"
V72G-2AK-NMN
0.73 (0.33)
3/8" V72G-3AK-NMN
0.73
(0.33)
V 7 2
-
G
★ ★
-
★
★
N
★
Port Size
Substitute
1/4"
2
3/8"
3
Threads
Substitute
PTF
A
ISO Rc taper
B
ISO G parallel
G
Gauge
Substitute
With
G
Without
N
Alternative Models
Outlet Pressure Adjustment Range*
Substitute
5 to 30 psig (0.3 to 2 bar)
C
5 to 60 psig (0.3 to 4 bar)
F
5 to 150 psig (0.3 to 10 bar)
M
*
Relief valve can be adjusted to pressures in
excess of and less than those specified. Do not
use these units to control pressures outside of
the specified ranges.
Adjustment
Substitute
Knob
K
T-bar
T
ISO Symbol