Norgren V74G Series Installation Instructions User Manual
V74g
![background image](/manuals/467609/1/background.png)
ASSEMBLY
1. Lubricate o-ring (15), adjusting screw threads and tip of
adjusting screw (5, 7), and the outer circumference and
both sides of the thrust washer (4) with a light coat of
good quality o-ring grease.
2. Assemble the unit as shown on the exploded view.
3. Torque Table
Torque in
Item
N-m (Inch-Pounds)
2, 10 (Screw)
2,8 to 3,9 (25 to 35)
14 (Bottom plug)
2,3 to 3,4 (20 to 30)
WARNING
These products are intended for use in industrial
compressed air systems only. Do not use these products
where pressures and temperatures can exceed those listed
under Technical Data.
To provide overpressure protection for pneumatic
equipment, the flow capacity of the relief valve selected for
a specific application must be greater than the maximum
possible flow rate of the system connected to the inlet of
the valve.
The accuracy of the indication of pressure gauges can
change, both during shipment (despite care in packaging)
and during the service life. If a pressure gauge is to be
used with these products and if inaccurate indications may
be hazardous to personnel or property, the gauge should be
calibrated before initial installation and at regular intervals
during use.
Before using these products with fluids other than air,
for non industrial applications, or for life-support systems
consult Norgren.
TECHNICAL DATA
Fluid: Compressed air
Operating temperature*: -20° to +80°C (0° to +175°F)
* Air supply must be dry enough to avoid ice formation at
temperatures below 2°C (35°F).
Gauge ports:
1⁄4 PTF with PTF main ports
Rc1/4 with ISO Rc main ports
Rc1/8 with ISO G main ports
Materials:
Body: Aluminum
Bonnet: Aluminum
Valve: Aluminum and Nitrile
Elastomers: Nitrile
Bottom plug: Acetal
REPLACEMENT ITEMS
Service kit (includes items circled
on exploded view) ..............................................4384-700
Tamper resistant cover (knob adjustment only).......4355-51
PANEL MOUNTING DIMENSIONS
Panel mounting hole diameter: 52 mm (2.06")
Panel thickness: 2 to 6 mm (0.06" to 0.25")
INSTALLATION
1. Shut off air pressure. Install relief valve in air line -
●
with air flow in direction of arrow on body,
●
as close as possible to the device being serviced,
●
at any angle.
2. Connect piping to proper ports using pipe thread sealant
on male threads only. Do not allow sealant to enter
interior of relief valve.
3. Install a pressure gauge or plug the gauge ports.
WARNING
Do not cap or in any way restrict the outlet port of the
relief valve. Relief port must be open to atmosphere.
ADJUSTMENT
1. Turn relief valve adjustment clockwise to increase
pressure setting. Turn adjustment counterclockwise to
decrease pressure setting.
2. Always approach the desired pressure from a lower
pressure. When reducing from a higher to a lower
setting, first reduce to some pressure less than that
desired, then bring up to the desired pressure.
3. KNOB ADJUSTMENT. Push knob down to lock pressure
setting. Pull knob up to release. Install tamper resistant
cover (see Replacement Items) to make setting tamper
resistant.
4. T-HANDLE ADJUSTMENT. Tighten lock nut (8) to lock
pressure setting.
DISASSEMBLY
1. Shut off inlet pressure. Reduce pressure in inlet and
outlet lines to zero. Turn relief adjustment (1 or 7) fully
counterclockwise.
2. Relief valve can be disassembled without removal from
air line. Disassemble in general accordance with the item
numbers on exploded view.
CLEANING
1. Clean parts with warm water and soap.
2. Rinse and dry parts. Blow out internal passages in body
with clean, dry compressed air.
3. Inspect parts. Replace those found to be damaged.
IM-200.500
(4/98)
a subsidiary of IMI plc
© Norgren 1998
* Relief valve can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges.
1
18
19
16
9
7
8
10
11
6
14
15
17
13
12
5
4
2
3
V74G
Installation & Maintenance
Instructions
Pressure Relief Valve
V74G -
★★★ - N★★
Thread Form
A....PTF
B....ISO Rc taper
G....ISO G parallel
Port
3 ....3/8"
4 ....1/3"
6 ....3/4"
Spring (Relief Pressure Range) *
F ....0,3 to 4 bar (5 to 60 psig)
M...0,3 to 10 bar (5 to 150 psig)
S....0,7 to 17 bar (10 to 250 psig)
Gauge
G....With
N....Without
Adjustment
K....Knob
T ....T-bar