Norgren R72R Series Datasheets User Manual
R72g/r
See Section ALE-24 for Accessories
Littleton, CO USA
Phone 303-794-2611
www.norgren.com
R72G/R
● Excelon design allows in-line or modular installation
● Full flow gauge ports
● Balanced valve design for optimum pressure control
● Push to lock adjusting knob with tamper resistant
accessory
● R72R reverse flow option
● Modular installations with Excelon 72, 73, and 74
series can be made to suit particular applications
Excelon 72 Pressure Regulator
1/4", 3/8" Port Sizes
ALE-4-6
ISO Symbols
R72G Relieving
R72G Non Relieving
R72R Relieving
R72R Non Relieving
Ordering Information.
Models listed include unidirectional flow, PTF threads, knob adjustment, relieving diaphragm, 5 to 150 psig (0.3 to 10 bar)
outlet pressure adjustment range* with gauge.
† Typical flow with 150 psig (10 bar) inlet pressure, 90 psig (6.3 bar) set pressure and a 15 psig (1 bar) droop from set.
Port Size
Model
Flow
†
scfm (dm
3
/s)
Weight lb (kg)
1/4"
R72G-2AK-RMG
70 (33)
0.79 (0.36)
3/8"
R72G-3AK-RMG
70 (33)
0.79 (0.36)
R 7 2
-
★
★ ★
-
★
★
★
★
Port Size
Substitute
1/4"
2
3/8"
3
Threads
Substitute
PTF
A
ISO Rc taper
B
ISO G parallel
G
Diaphragm
Substitute
Relieving
R
Non relieving
N
Gauge
Substitute
With
G
Without
N
* Outlet pressure can be adjusted to pressures in excess of, and less than,
those specified. Do not use these units to control pressures outside of the
specified ra n g e s.
* 250 psi model only ava i l a ble with T- h a n d l e.
Adjustment
Substitute
Knob
K
T-bar
T
Alternative Models
Outlet Pressure Adjustment Range*
Substitute
5 to 30 psig (0.3 to 2 bar)
C
5 to 60 psig (0.3 to 4 bar)
F
5 to 150 psig (0.3 to 10 bar)
M
10 to 250 (0.6 to 17 bar)*
Flow Type
Substitute
Standard
G
Reverse flow
R