11-002
●
Large diaphragm provides accurate and quick
response to changing flow demands and line
pressure
●
Floating valve pin provides positive valve seating
●
Balanced valve minimizes effect of variations in inlet
pressure on outlet pressure
●
Standard relieving models allow reduction of
downstream pressure when the system is
dead-ended
Pressure Regulator
1/4", 3/8", 1/2" Port Sizes
Port Size
Model Number
Flow
†
scfm (dm
3
/s)
Weight lbs (kg)
1/4"
11-002-013
110 (52)
1.9 (0.86)
3/8"
11-002-037
110 (52)
1.9 (0.86)
1/2"
11-002-061
260 (123)
2.0 (0.91)
Ordering Information.
Models listed have PTF threads, T-bar adjustment, relieving diaphragm, and 5 to 125 psig (0.3 to 8.5 bar) outlet
pressure adjustment range*.
† Typical flow with 150 psig (10 bar) inlet pressure, 90 psig (6.3 bar) set pressure and 15 psig (1 bar) droop from set.
*Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges.
Alternative Models
Threads
Substitute
PTF
0
ISO G parallel
8
ISO G Rc
9
0
★
-
★
★ ★
★ ★
2 -
-
1
1
Option
Substitute
Handwheel adjustment
8C
Screw adjustment
8B
Mounting bracket assembled to unit
1A
Threaded bonnet for panel mounting, hand wheel adjustment
2A
Threaded bonnet for panel mounting, T-bar adjustment
2B
Threaded bonnet for panel mounting, screw adjustment
2C
Outlet Pressure Adjustment Range*
5 to 50 psig (0.3 to 3.5 bar)
Port Size Relief Type
Gauge
Substitute
1/4"
Non-relieving
Without
003
1/4"
Relieving
Without
015
3/8"
Non-relieving
Without
027
3/8"
Relieving
Without
039
1/2"
Non-relieving
Without
051
1/2"
Relieving
Without
063
1/4"
Non-relieving
With
009
1/4"
Relieving
With
021
3/8"
Non-relieving
With
033
3/8"
Relieving
With
045
1/2"
Non-relieving
With
057
1/2"
Relieving
With
069
Outlet Pressure Adjustment Range*
5 to 125 psig (0.3 to 8.5 bar)
Port Size Relief Type
Gauge
Substitute
1/4"
Non-relieving
Without
001
1/4"
Relieving
Without
013
3/8"
Non-relieving
Without
025
3/8"
Relieving
Without
037
1/2"
Non-relieving
Without
049
1/2"
Relieving
Without
061
1/4"
Non-relieving
With
007
1/4"
Relieving
With
019
3/8"
Non-relieving
With
031
3/8"
Relieving
With
043
1/2"
Non-relieving
With
055
1/2"
Relieving
With
067
Outlet Pressure Adjustment Range*
5 to 250 psig (0.3 to 17 bar)
Port Size Relief Type
Gauge
Substitute
1/4"
Non-relieving
Without 005
1/4"
Relieving
Without
017
3/8"
Non-relieving
Without
029
3/8"
Relieving
Without
041
1/2"
Non-relieving
Without
053
1/2"
Relieving
Without
065
1/4"
Non-relieving
With
011
1/4"
Relieving
With
023
3/8"
Non-relieving
With
035
3/8"
Relieving
With
047
1/2"
Non-relieving
With
059
1/2"
Relieving
With
071