* Table
– AMS_ERROR_CODE (TICU error codes)
Error
Error
Code
Description
AMS_CODE _OK
80H
Normal Response
AMS_CODE_STX_ERROR
81H
Start of Text Error
AMS_CODE_ETX_ERROR
82H
End of Text Error
AMS_CODE_MFR_ERROR
83H
Incorrect MFR Error
AMS_CODE_SYS_GROUP_ERROR
84H
Incorrect System Group
AMS_CODE_SYS_NAME_ERROR
85H
Incorrect System Name
AMS_CODE_SYS_ID_ERROR
86H
Incorrect TICU System ID
AMS_CODE_SYS_SUB_ID_ERROR
87H
Incorrect System Sub ID or unknown Sub ID
AMS_CODE_PROVER_ERROR
88H
Incorrect Protocol Version
AMS_CODE_CMD_ERROR
89H
Unknown Command
AMS_CODE_CMDSUB_ERROR
8AH
Unknown Sub Command
AMS_CODE_FAIL
8BH
Abnormal Response
AMS_CODE_CRC_ERROR
8CH
CRC Error
AMS_CODE_UNKNOWN_DEVICE_ID
8DH
Non existence of specified TICU or ALD
AMS_CODE_NETWORK_LINK
8EH
NOT_USED
AMS_CODE_SCANNING
8FH
TICU scanning in progress for ALD
AMS_CODE_485_BUSY
90H
TICU awaiting response from ALD
(can’t send any
commands)
AMS_CODE_CMD_SEQUENCE_ERROR
91H
Download fail to TICU
– Block and Sequence error
AMS_CODE_DOWNLOAD_FAIL
92H
Download fail to TICU
– TICU timed-out
AMS_CODE_EERPOM_NOT_INITIAL
93H
TICU EEPROM is not Initialized
AMS_CODE_EERPOM_VER_ERROR
94H
TICU EEPROM Version Error
AMS_CODE_EEPROM_ERROR
95H
TICU EEPROM Write Error
AMS_CODE_DATA_LENGTH_ERROR
96H
Data length error
AMS_CODE_ALD_BUSY
97H
ALD busy
–can’t execute the command
AMS_CODE_DATA_ERROR
98H
TICU data error