Ticu information, Confidential – KMW Communications AMS Lite User Manual
Page 11

Sheet 11 of 30
Sheet 11 of 30 8/17/2008
©
CONFIDENTIAL
Unknown Procedure
Received procedure code is not defined
TMA Minor Fault
A fault in the TMA subunit is detected which reduces the gain
performance but maintains its function.
[SU 1]: SubUnit1 (Main Path) [YRMIN]
[SU 2]: SubUnit2 (Diversity Path)
TMA Major Fault
LNA alarm, TDD S/W alarm
[SU 1]: SubUnit1 (Main Path)
[SU 2]: SubUnit2 (Diversity Path)
Unsupported Value
The requested value is not supported.
Read Only
Invalid device data parameter usage
Unknown Parameter
Specified parameter is not supported for the used procedure
Bypass Mode
The TMA subunit is in bypass mode and cannot report a correct
gain value.
[SU 1]: SubUnit1 (Main Path)
[SU 2]: SubUnit2 (Diversity Path)
Working S/W Missing
The unit is in Download Mode state. Returned upon unsupported
procedure when in Download Mode state
Invalid File Content
The data being downloaded is detected to be of wrong format or
size
Format Error
Procedure message is inconsistent or if an addressed field or
antenna is invalid or the data parameter field length is
inconsistent with the corresponding field length parameter
Unsupported
Procedure
The procedure is optional and not supported or the procedure
does not apply to this device type
Invalid
Procedure
Sequence
Procedure sequence as described in annex C is expected but
not experienced by the secondary device
Actuator Interference
An actuator movement outside the control of the RET unit has
been detected. Probable cause is manual interference
) TICU information
Displays TICU information
Table
– TICU Information
ITEM
Description
Remark
ID
TICU ID
1 ~ 65535