- AISG v2.0 7.1
0x01: RET
0x02: TMA
Maker
ALD Manufacturer
2Byte
Serial
ALD Serial NO.
17Byte
Model
ALD Model
15Byte
ROM Ver
ALD S/W Version
H/W Ver
ALD H/W Version
Tilting Deg.
Antenna Tilt Degree
Steering Deg.
Antenna Azimuth Degree
TMA Gain
Gain
13dB Fixed
Link Alarm
Normal: Green, Alarm: Red
Communication error.
(When disconnected or
the information between ALD and
TICU are different)
Connect
Connect: Green, Not Connected: Red
) Alarm Code List
Displays return codes specified in AISG 2.0.
- 3GPP TS 25.463 V6.4.0 Annex A: Return codes for secondary devices
- AISG Standard No. AISG v2.0 Annex B: Return Codes for AISG ALDs
ITEM
Description
Remark
Motor Jam
Motor cannot move
Actuator Jam
Actuator jam has been detected. No movement of the actuator,
but movement of the motor was detected
Busy
The device is busy and cannot respond until an ongoing activity
is completed
CheckSum Error
Checksum incorrect for otherwise valid data.
Not Calibrated
The device has not completed a calibration operation, or
calibration has been lost
Not Configured
Actuator configuration data is missing
Hardware Error
Any hardware error, which cannot be classified. May not be
reported as an alarm until the fault is likely to be persistent
Out of Range
A parameter given by an operator (e.g. tilt value or memory
offset) is out of range