Confidential – KMW Communications AMS Lite User Manual
Page 17

Sheet 17 of 30
Sheet 17 of 30 8/17/2008
©
CONFIDENTIAL
executed successfully.
AISG_RET_CODE_NOT_CALIBRA
TED
0EH
The device has not completed a calibration operation, or calibration
has been lost.
AISG_RET_CODE_NOT_CONFIG
URED
0FH
Actuator configuration data is missing.
AISG_RET_CODE_HARDWARE_E
RROR
11H
Any hardware error which cannot be classified. May not be reported
as an alarm until the fault is likely to be persistent.
AISG_RET_CODE_OUT_OF_RAN
GE
13H
A parameter given by an operator (e.g. tilt value or memory offset) is
out of range.
AISG_RET_CODE_UNKNOWN_P
ROCEDURE
19H
Received procedure code is not defined.
AISG_RET_CODE_MINOR_TMA_F
AULT
1AH
A fault in the TMA subunit is detected which reduces the gain
performance but maintains its function.
AISG_RET_CODE_MAJOR_TMA_
FAULT
1BH
A fault in the TMA subunit is detected. The fault prevents the function
of the TMA subunit.
AISG_RET_CODE_UNSUPPORTE
D_VALUE
1CH
The requested value is not supported.
AISG_RET_CODE_READ_ONLY
1DH
Invalid device data parameter usage.
AISG_RET_CODE_UNKNOWN_PA
RAMETER
1EH
Specified parameter is not supported for the used procedure.
AISG_RET_CODE_BYPASS_MOD
E
1FH
The TMA subunit is in bypass mode and cannot report a correct gain
value.
AISG_RET_CODE_WORKING_SO
FTWARE_MISSING
21H
The unit is in DownloadMode state. Returned upon unsupported
procedure when in DownloadMode state.
AISG_RET_CODE_INVALID_FILE_
CONTENT
22H
The data being downloaded is detected to be of wrong format or
size.
AISG_RET_CODE_FORMAT_ERR
OR
24H
Procedure message is inconsistent or if an addressed field or
antenna is invalid or the data parameter field length is inconsistent
with the corresponding field length parameter.
AISG_RET_CODE_UNSUPPORTE
D_PROCEDURE
25H
The procedure is optional and not supported or the procedure does
not apply to this device type.
AISG_RET_CODE_INVALID_PRO
CEDURE_SEQUENCE
26H
Procedure sequence as described in annex C is expected but not
experienced by the secondary device.
AISG_RET_CODE_ACTUATOR_IN
TERFERENCE
27H
An actuator movement outside the control of the RET unit has been
detected. Probable cause is manual interference.