SWITCHING CHARACTERISTICS

T

A

= -40 to +85 °C; V1+ = V2+ = +2.5 V, ±5%; V1- = V2- = -2.5 V, ±5%;

VL - VLR = 3.3 V, ±5%, 2.5 V, ±5%, or 1.8 V, ±5%
Input levels: Logic 0 = 0V = Low; Logic 1 = VD+ = High; CL = 15 pF.

9.

Reset must not be released until the power supplies and the voltage reference are within specification.

10.

BP/UP can be changed coincident to CONV falling. BP/UP must remain stable until RDY falls.

11.

If CONV is held low continuously, conversions occur every 160 MCLK cycles.

If RDY is tied to CONV, conversions will occur every 162 MCLKs.
If CONV is operated asynchronously to MCLK, a conversion may take up to 164 MCLKs.
RDY falls at the end of conversion.

Parameter

Symbol Min Typ

Max

Unit

Master Clock Frequency

Internal Oscillator

External Clock

XIN

f

clk

12

0.5

14
16

16

16.2

MHz
MHz

Master Clock Duty Cycle

40

-

60

%

Reset

RST Low Time

(Note 9)

t

res

1

-

-

µs

RST rising to RDY falling

Internal Oscillator

External Clock

t

wup

-
-

120

1536

-
-

µs

MCLKs

Conversion

CONV Pulse Width

t

cpw

4

-

-

MCLKs

BP/UP setup to CONV falling

(Note 10)

t

scn

0

-

-

ns

CONV low to start of conversion

t

scn

-

-

2

MCLKs

Perform Single Conversion (CONV high before RDY falling)

t

bus

20

-

-

MCLKs

Conversion Time

(Note 11)

Start of Conversion to RDY falling

t

buh

-

-

164

MCLKs