3.0 REGISTER DESCRIPTION

3.1 DIFFERENTIAL DC OFFSET CALIBRATION

Mode Control Register (address 01h)

Access:

R/W in I

2

C and SPI.

Default:

0 - Disabled

Function:

Enabling this function will initiate a calibration to minimize the differential DC offset. This function will be
automatically reset following completion of the calibration sequence.

3.2 SOFT MUTE

Mode Control Register (address 01h)

Access:

R/W in I

2

C and SPI.

Default:

0 - Enabled

Function:

The analog outputs will ramp to a muted state when enabled. The ramp requires 1152 left/right clock cy-
cles in Single Speed, 2304 cycles in Double Speed and 4608 cycles in Quad Speed mode. The bias volt-
age on the outputs will be retained and MUTEC will go low at the completion of the ramp period.

The analog outputs will ramp to a normal state when this function transitions from the enabled to disabled
state. The ramp requires 1152 left/right clock cycles in Single Speed, 2304 cycles in Double Speed and
4608 cycles in Quad Speed mode. The MUTEC will go high immediately on disabling of MUTE.

7

6

5

4

3

2

1

0

CAL

MUTE

M4

M3

M2

M1

M0

PDN

CAL

MODE

0

Disabled : CAL complete

1

Enabled : CAL initiated

Table 1.

7

6

5

4

3

2

1

0

CAL

MUTE

M4

M3

M2

M1

M0

PDN

MUTE

MODE

0

Enabled

1

Disabled

Table 2.