Applications, 1 sample rate range/operational mode select, 1 stand-alone mode – Cirrus Logic CS4360 User Manual
Page 21: 2 control port mode, 2 system clocking, 1 stand-alone mode 4.1.2 control port mode, Cs4360
CS4360
DS517F2
21
4. APPLICATIONS
4.1
Sample Rate Range/Operational Mode Select
4.1.1
Stand-Alone Mode
The device operates in one of four operational modes determined by the Mode pins in Stand-alone mode.
Sample rates outside the specified range for each mode are not supported.
4.1.2
Control Port Mode
The device operates in one of three operational modes determined by the FM bits (see section 6.1.4) in
Control Port mode. Sample rates outside the specified range for each mode are not supported.
4.2
System Clocking
The device requires external generation of the master (MCLK), left/right (LRCK) and serial (SCLK) clocks.
The LRCK, defined also as the input sample rate (F
s
), must be synchronously derived from the MCLK
according to specified ratios. The specified ratios of MCLK to LRCK, along with several standard audio
sample rates and the required MCLK frequency, are illustrated in Tables 3-5.
Sample Rate
(kHz)
MCLK (MHz)
256x
384x
512x
768x
1024x*
32
8.1920
12.2880
16.3840
24.5760
32.7680
44.1
11.2896
16.9344
22.5792
33.8688
45.1584
48
12.2880
18.4320
24.5760
36.8640
49.1520
Table 3. Single-speed Mode Standard Frequencies
Sample Rate
(kHz)
MCLK (MHz)
128x
192x
256x
384x
512x*
64
8.1920
12.2880
16.3840
24.5760
32.7680
88.2
11.2896
16.9344
22.5792
33.8688
45.1584
96
12.2880
18.4320
24.5760
36.8640
49.1520
Table 4. Double-speed Mode Standard Frequencies
M2
M1
Input Sample Rate (F
S
)
MODE
0
0
4 kHz - 50 kHz
Single-Speed (without De-emphasis)
0
1
32 kHz - 48 kHz
Single-Speed (with De-emphasis)
1
0
50 kHz - 100 kHz
Double-Speed
1
1
100 kHz - 200 kHz
Quad-Speed
Table 1. CS4360 Stand-Alone Operational Mode
FM1
FM0
Input Sample Rate (F
S
)
MODE
0
0
4 kHz - 50 kHz
Single-speed
0
1
50 kHz - 100 kHz
Double-speed
1
0
100 kHz - 200 kHz
Quad-speed
1
1
Reserved
Reserved
Table 2. CS4360 Control Port Operational Mode