beautypg.com

Design and function – WIKA TW61 User Manual

Page 9

background image

WIKA operating instructions thermowell, model TW61

11593963.03 03/2014 GB/D/F/E

9

GB

4. Design and function

Nominal

width of

tube

Nominal

pressure

in bar

Outer

diameter

of pipe

Tube wall

thickness

Tube

length

Thermowell

insertion

length

Neck tube length

TR21-B TR22-B

OD

PN

1) 2)

Ø D

s

TL

U

1

M

M

13.5

25

13.5

1.6

64

6

51

129

17.2

25

17.2

1.6

68

9

48

126

21.3

25

21.3

1.6

72

11

46

124

26.9

25

26.9

1.6

110

11

46

124

33.7

25

33.7

2.0

120

18

39

117

42.4

25

42.4

2.0

130

18

39

117

48.3

25

48.3

2.0

130

18

39

117

60.3

25

60.3

2.0

180

30

27

105

76.1

16

76.1

2.0

220

30

27

105

88.9

16

88.9

2.3

260

45

12

90

ISO tubes or DIN 11866 series B

Nominal

width of

tube

Nominal

pressure

in bar

Outer

diameter

of pipe

Tube wall

thickness

Tube

length

Thermowell

insertion

length

Neck tube length

TR21-B TR22-B

OD

PN

1) 2)

Ø D

s

TL

U

1

M

M

10

25

13

1.5

70

6

51

129

15

25

19

1.5

70

9

48

126

20

25

23

1.5

80

11

46

124

25

25

29

1.5

100

18

39

117

32

25

35

1.5

110

18

39

117

40

25

41

1.5

120

18

39

117

50

25

53

1.5

160

30

27

105

65

16

70

2.0

210

30

27

105

80

16

85

2.0

260

45

12

90

100

12.5

104

2.0

310

45

12

90

Metric or DIN 11866 series A

Nominal

width of

tube

Nominal

pressure

in bar

Outer

diameter

of pipe

Tube wall

thickness

Tube

length

Thermowell

insertion

length

Neck tube length

TR21-B TR22-B

OD

PN

1) 2)

Ø D

s

TL

U

1

M

M

½"

13.8

12.7

1.65

95.2

6

51

129

¾"

13.8

19.05

1.65

101.6

9

48

126

1"

13.8

25.4

1.65

108.0

11

46

124

1 ½"

13.8

38.1

1.65

120.6

18

39

117

2"

13.8

50.8

1.65

146.0

18

39

117

2 ½"

13.8

63.5

1.65

158.8

30

27

105

3"

13.8

76.2

1.65

171.4

30

27

105

4"

13.8

101.6

2.11

209.6

45

12

90

ASME BPE or DIN 11866 series C

1) Maximum operating temperature 150 °C

2) All thermowells of this model series which are exposed to internal pressure and have a nominal diameter (DN) of > 25 mm are

manufactured and tested in accordance with module H of the pressure equipment directive 97/23/EC.