Specifications / 4. design and function, Specifications, Design and function – WIKA TW61 User Manual

Page 7

background image

WIKA operating instructions thermowell, model TW61

11593963.03 03/2014 GB/D/F/E

7

GB

3. Specifications

Specifications

Model TW61

Designs of connection

Flow-through housing or angular housing

Nominal width of tube

Pipe classes per DIN, ISO and ASME BPE

see table of dimensions, chapter 4.2 “Dimensions and

pressure ratings”

Permissible temperature ranges

Ambient

Medium to be measured

-40 ... +85 °C

-50 ... +250 °C

Materials (wetted parts)

Pipes to DIN 11866 series A (metric) and

series B (ISO)

Pipes to DIN 11866 series C (ASME BPE)

Stainless steel 1.4435

Stainless steel 316L

Connection to the thermometer

Model TR21-B: G 3/8 male

Model TR22-B: M24 x 1.5 rotatable male nut

For further specifications see WIKA data sheet TW 95.61 and the order documentation.

4. Design and function

4.1 Description

The model TW61 thermowell is used to adapt thermometers and measuring inserts to the

process and protects the sensor against harsh process conditions. Furthermore, it enables the

removal of the temperature sensor without having to open the process.

To integrate it into the process, the thermowell is directly orbitally-welded into a pipeline. The

connection ends are smooth and prepared for orbital welding.

In combination with a resistance thermometer, the rotatable threaded connection of the

connection head or the display can be loosened and turned to the desired orientation. The

measuring insert can be withdrawn together with the connection head. In this way, it is possible to

calibrate the entire measuring chain (sensor, transmitter if applicable, connection cable) on site,

without having to disconnect the electrical connection. In addition this avoids having to open the

process, and thus the risk of contamination is minimised.

The thermowell is not piggable.