beautypg.com

Gb 8. technical data, Technical data – WIKA 891.34.2189 User Manual

Page 9

background image

GB

8. Technical data

Technical data

DELTA-trans, Model 891.34.2189

Differential measuring range

bar

0 ... 0.16 to 0 ... 25

Working pressure (stat.) max.

bar

25

Overload value either side max. bar

25

Pressure connections

exposed
to medium

2 x G ¼ female, bottom, in-line, centre distance 26 mm (optional: other
pressure connections male or female or compression fitting with ferrule for
pipe Ø 6, 8 or 10 mm respectively)

Pressure media chamber

exposed to medium

GD-AlSi 12 (Cu) 3.2982, black painted (optional GD-AlSi 12 (Cu) HARD-COAT
surface protection or stainless steel)

Press. element comp. spring

stainless steel 1.4310 or FD SiCr EN 10 270-2

Press. element separ. diaphr.

FPM/FKM fabric back stay (optional NBR)

Links

stainless steel 1.4305, FPM/FKM (optional NBR)

Sealing rings

FPM/FKM (optional NBR)

Press. equalising valve
(optional)

stainless steel and FPM/FKM

4-way valve manifold
(optional)

Cu-alloy or stainless steel, 1x Press. equalising valve, 2 x gauge valve,
1 x valve for purging or air bleeding

Power supply U

B

DC V

10

< U

B

≤ 30 (optional LCD-display 14 < U

B

≤ 30)

Permissible residual ripple

≤ 0.1 % of span/10 V

Supply voltage effect

% ss

≤ 10

Output signal and permissible
max. load R

A

4 … 20 mA, 2-wire system R

A

≤ (U

B

- 10 V) / 0.02 A with R

A

in Ohm and U

B

in Volt

0 … 20 mA, 3-wire system R

A

≤ (U

B

- 10 V) / 0.02 A with R

A

in Ohm and U

B

in Volt

Effect of load

% of span

≤ 0.1

Response time

s

approx. 1 (optional approx. 50 ms)

Output signal adjustment

Zero point, electrical

% of span

± 15

Span, electrical

% of span

± 30

Linearity

% of span

2.5 (limit point calibration)

(including hysteresis)

optional 1.6 (limit point calibration)

Permissible

Medium temperature

°C

+80 maximum

Ambient temperature

°C

-10 … +60 (optional LCD-display 0 … 50)

Compensated temp. range

°C

-10 … +60 (optional LCD-display 0 … 50)

Temperature coefficient in
compensated temp. range

Average T

K

on zero point

≤ 0.4 % of span/10 K

Average T

K

on span

≤ 0.4 % of span/10 K

LCD-display (optional)

Voltage load

DC V

3.5

Display

3 ½-digit, height 12.7

Ambient temperature

°C

0 … 50

Storage temperature

°C

-10 … +80

Wiring

Terminal box (screw terminals up tu 2.5 mm²)

Wiring protection

Protected against reverse polarity and overvoltage

EMC (electro-magnetic
compatibility)

Interference emission per EN 50 081 - 1 (March 93) and EN 50 081 - 2 (March 94),
Interference immunity per EN 50 082 - 2 (March 95)

Ingress protection

IP 54 (optional IP 65) according EN 60 529 / IEC 529

Weight

kg

approx. 1.3

2279453 08/2009 GB/D/F

WIKA Operating Instructions Differential Pressure Transmitter DELTA-trans

9

8. Technical data