Specifications – WIKA PSA-31 User Manual
Page 12
12
WIKA operating instructions pressure switch model PSA-31
GB
14018458.01 11/2011 GB/D/F/E
3. Specifications
Temperature coefficients depending on the process connection
Clamp DIN 32676, DN 32
Typical temperature coefficient of zero point
■
0 ... 20 °C
■
20 ... 80 °C
0.75 % of span / 10 K
0.45 % of span / 10 K
Typical temperature coefficient of span
■
0 ... 80 °C
0.1 % of span / 10 K
All other process connections
Typical temperature coefficient of zero point
■
0 ... 20 °C
■
20 ... 80 °C
0.7 % of span / 10 K
0.2 % of span / 10 K
Typical temperature coefficient of span
■
0 ... 80 °C
0.1 % of span / 10 K
3.6 Reference conditions
Temperature:
15 ... 25 °C
Atmospheric pressure: 950 ... 1,050 mbar
Humidity:
45 ... 75 % relative
Nominal position:
Process connection lower mount
Power supply:
DC 24 V
Load:
see "Output signal"
3.7 Operating conditions
Temperatures and humidity
Ambient temperature:
-20 ... +80 °C
Storage temperature:
-20 ... +80 °C
Rated temperature range: 0 ... 80 °C
Permissible humidity:
45 ... 75 % relative