Check the hold of the wires in the terminals by lightly pulling on
them
10 Connect the screen to the internal ground terminal, connect the
outer ground terminal with potential equalisation
11 Tighten the compression nut of the cable entry. The seal ring must
completely encircle the cable
12 Screw the housing cover on
The electrical connection is finished.
5
.3 Single chamber housing
2
1
Display
4...20mA
1
2
Fig. 6: Electronics and connection compartment with single chamber housing
1
Spring-loaded terminals for voltage supply
2
Ground terminal for connection of the cable screen
Electronics and connec-
tion compartment
16
Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor • 4 … 20 mA
5 Connecting to power supply