Fixing the installation plate, Optional accessories, Tools required for installation – Sunlight Supply Samsung Linesets for Mini Split Systems User Manual
Page 27: General tools, Tools for test operations

ENGLISH
27
The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air
conditioner.
Optional accessories
• Make sure to drill only one
hole after choosing the
direction of the pipe.
Fixing the installation plate
Tools required for installation
Insulated
Assembly Pipe,
Ø1/4inch (Ø6.35mm)
(1)
Insulated Assembly Pipe,
Ø3/8inch(9.52mm) (1)
09/12
Insulated Assembly Pipe,
Ø 1/2inch(12.70mm) (1)
18
Insulated Assembly Pipe,
Ø 5/8inch(15.88mm) (1)
24/36
PE T3 Foam Tube
Insulation (1)
Vinyl Tapes (2)
Drain Plug (1)
Rubber Legs (4)
Pipe Clamps A (3)
Pipe Clamps B (3)
Cement Nails (6)
M0.16 x 0.98
(M4 x 25) Tapped
Screws (6)
Drain Hose,
length 6.56ft(2m) (1)
Putty 100g (1)
Foam
Insulation
(1)
Wired remote
controller (1)
Sub COMM PBA
General Tools
• Vacuum Pump(Backward flowing prevention)
• Manifold Gauge
• Stud Finder
• Torque Wrench
• Pipe Cutter
• Reamer
• Pipe Bender
• Spirit Level
• Screw Driver
• Spanner
• Drill
• Wrench
• Measuring Tape
Tools for test operations
• Thermometer
• Resistance Meter • Electroscope
You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing
the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable,
pipe and hose pass to connect the indoor unit to the outdoor unit.
When facing the wall, the pipe and cable can be connected from the:
• Right (A)
• Left (B)
• Underside_right (C)
• Rear_right or left (D)
B
A
D
C
D
Direction of pipe
1. Determine the position of the pipe and drain hose hole as seen in the
picture and drill the hole with an inner diameter of 65mm so that it slants
slightly downwards.
B
A
D
C
Pipe hole
(Ø2.56inch
(65mm))
(Unit : inch(mm))
Model
A
B
C
D
09/12 1.06
(27)
4.72
(120)
2.68
(68)
1.06
(27)
18/24 1.34
(34)
5.51
(140)
2.68
(68)
1.34
(34)
A
C
F
E
D
B
36
(Unit : inch(mm))
Model
A
B
C
D
36
6.14
(156)
2.64
(67)
14.33
(364)
1.36
(34.5)
E
F
2.54
(64.5)
0.77
(19.5)
09/12/18/24
• If these accessories are supplied, they will be in the
accessory box.
• Wired remote controller is optional. It has no Filter Reset
function in this model.
•
At cool mode, when wireless Remote controller temp
setting is from 61
o
F~64
o
F, wired Remote controller
can display the setting temp correctly, but can't set
TEMP below from 64
o
F to 61
o
F .
Vivaldi MAX_AQN09VFU@@ IB&IM_32163A_E.indd 27
2012-6-20 13:28:56